Reviewed Papers
Open stats →
Harm pubmed · Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases · 2007

[Effects of different dose microwave radiation on protein components of cultured rabbit lens].

Lens transparency decreased after microwave exposure, with obvious cortex opacification reported at 5.00 mW/cm^2 for 8 hours. At 1.00, 2.00, and 5.00 mW/cm^2, WSP percentage decreased while USP increased; ASP showed no change, and SP decreased at 5.00 mW/cm^2…

[Effects of different dose microwave radiation on protein components of cultured rabbit lens].
Harm pubmed · Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases · 2007

[Influence of microwave radiation on synaptic structure and function of hippocampus in Wistar rats].

Rats exposed to microwave radiation at an average power density of 30 mW/cm(2) showed synaptic ultrastructural alterations in the hippocampus at 6 h post-exposure (including synaptic vesicle deposits, active zone elongation, increased postsynaptic density thi…

[Influence of microwave radiation on synaptic structure and function of hippocampus in Wistar rats].
Harm pubmed · Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases · 2007

[Effects of microwave radiation on lens hydration and expression of PKC-alpha and transcription factors in lens epithelial cells].

Rabbit lenses exposed in vitro to 2450 MHz microwaves at 2.0 and 5.0 mW/cm(2) showed increased lens hydration versus controls and morphological/nuclear changes in lens epithelial cells; 0.5 mW/cm(2) showed no reported changes. At 2.0 mW/cm(2), PKC-alpha expre…

[Effects of microwave radiation on lens hydration and expression of PKC-alpha and transcription factors in lens epithelial cells].
Harm pubmed · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2007

Dependence of RF heating on SAR and implant position in a 1.5T MR system.

In gel phantoms with a stainless steel humerus implant, temperature rise at the implant tip increased linearly with SAR (reported 6.4°C at 2.0 W/kg and 12.7°C at 4.0 W/kg). Heating decreased steeply when the implant angle relative to B0 exceeded 45°, and decr…

Dependence of RF heating on SAR and implant position in a 1.5T MR system.