Exposure of rats to extremely low-frequency electromagnetic fields (ELF-EMF) alters cytokines production.

PAPER pubmed Electromagnetic biology and medicine 2013 Animal study Effect: mixed Evidence: Low

Abstract

Investigations indicate a potential link between exposure to extremely low-frequency electromagnetic field (ELF-EMF) and some cancers. Carcinogenesis of ELF-EMF may be mediated by effect on the immune system. During an immune response, naïve T cells differentiate to effector type 1 helper T cells (T(H)1), T(H)2, or T(H)17 subsets according to existence of different cytokines and T(H)1 is important in defense against tumors. Therefore, it will be reasonable to test whether ELF-EMF can change cytokines like interferon gamma (IFN-γ), interleukin-4 (IL-4), IL-6, and IL-12 that regulate T(H)1/T(H)2/T(H)17 balance. Forty adult male rats were randomly separated into ELF-EMF-exposed and sham-exposed control groups. The ELF-EMF group was exposed to a flux density of 100 μT, frequency 50 Hz, 2 h/day for 3 months. The controls were placed in identical chamber without ELF-EMF. The results showed there were no significant differences between the mean mass of rats, thymuses, and spleens in ELF-EMF exposed group compared with controls. Serum IL-12 level was decreased from 418 ± 47 pg/ml in controls to 300 ± 23 pg/ml (p < 0.05) in ELF-EMF-exposed group. Phytohemagglutinin activated of in vitro production of IL-6 by the whole spleen culture (1356 ± 92 pg/ml) and total blood culture (418 ± 40 pg/ml) of ELF-EMF-exposed rats were higher (p < 0.001) comparing with controls (905 ± 74 pg/ml), (182 ± 26 pg/ml), respectively. However, the levels of IFN-γ, IL-4, and IL-6 of serum and IFN-γ, IL-4, and IL-12 in spleen culture and total blood culture of two groups were not significantly different. It seems that ELF-EMF may change T(H)1/T(H)2/T(H)17 balance toward down regulation of T(H)1 and upregulation T(H)17 type responses.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Forty adult male rats
Sample size
40
Exposure
ELF · 0.05 MHz · 2 h/day for 3 months
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Rats exposed to 50 Hz ELF-EMF at 100 μT for 2 h/day for 3 months showed no significant differences in body, thymus, or spleen mass versus sham controls. Serum IL-12 was lower in exposed rats (300±23 pg/ml) than controls (418±47 pg/ml; p<0.05), and phytohemagglutinin-stimulated IL-6 production was higher in spleen and blood cultures from exposed rats (p<0.001), while several other cytokine measures (including IFN-γ and IL-4) were not significantly different.

Outcomes measured

  • Serum cytokines (IL-12, IFN-γ, IL-4, IL-6)
  • In vitro cytokine production in whole spleen culture and total blood culture (IL-6, IFN-γ, IL-4, IL-12) after phytohemagglutinin activation
  • Body mass
  • Thymus mass
  • Spleen mass

Limitations

  • Only adult male rats were studied
  • Some outcomes showed no significant differences while others did, suggesting outcome-specific effects
  • In vitro cytokine production assays may not directly reflect in vivo immune function

Suggested hubs

  • elf-emf (0.9)
    Animal experiment with extremely low-frequency EMF exposure (50 Hz, 100 μT) assessing immune/cytokine outcomes.
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "ELF",
        "source": null,
        "frequency_mhz": 0.05000000000000000277555756156289135105907917022705078125,
        "sar_wkg": null,
        "duration": "2 h/day for 3 months"
    },
    "population": "Forty adult male rats",
    "sample_size": 40,
    "outcomes": [
        "Serum cytokines (IL-12, IFN-γ, IL-4, IL-6)",
        "In vitro cytokine production in whole spleen culture and total blood culture (IL-6, IFN-γ, IL-4, IL-12) after phytohemagglutinin activation",
        "Body mass",
        "Thymus mass",
        "Spleen mass"
    ],
    "main_findings": "Rats exposed to 50 Hz ELF-EMF at 100 μT for 2 h/day for 3 months showed no significant differences in body, thymus, or spleen mass versus sham controls. Serum IL-12 was lower in exposed rats (300±23 pg/ml) than controls (418±47 pg/ml; p<0.05), and phytohemagglutinin-stimulated IL-6 production was higher in spleen and blood cultures from exposed rats (p<0.001), while several other cytokine measures (including IFN-γ and IL-4) were not significantly different.",
    "effect_direction": "mixed",
    "limitations": [
        "Only adult male rats were studied",
        "Some outcomes showed no significant differences while others did, suggesting outcome-specific effects",
        "In vitro cytokine production assays may not directly reflect in vivo immune function"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "ELF-EMF",
        "50 Hz",
        "100 μT",
        "rats",
        "cytokines",
        "IL-12",
        "IL-6",
        "IFN-γ",
        "IL-4",
        "T(H)1",
        "T(H)2",
        "T(H)17",
        "immune system"
    ],
    "suggested_hubs": [
        {
            "slug": "elf-emf",
            "weight": 0.90000000000000002220446049250313080847263336181640625,
            "reason": "Animal experiment with extremely low-frequency EMF exposure (50 Hz, 100 μT) assessing immune/cytokine outcomes."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.