Share
𝕏 Facebook LinkedIn

An anatomically realistic voxel model of the pregnant woman and numerical dosimetry for a whole-body exposure to RF electromagnetic fields.

PAPER pubmed Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference 2006 Engineering / measurement Effect: unclear Evidence: Insufficient

Abstract

The numerical dosimetry of pregnant women is one of the most important issues in electromagnetic-field safety. We have recently developed a whole-body numerical female model of an adult Japanese (non-pregnant) average figure. Therefore, a new fetus model including inherent tissues of pregnant women was constructed based on abdominal MRI data of a 7-month pregnant woman. A whole-body pregnant woman model was developed by combining the new fetus and the female models. The anatomical details of the developed pregnant woman model and basic SAR characteristics for whole-body exposure to RF electromagnetic fields are demonstrated.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
unclear
Population
7-month pregnant woman (abdominal MRI data) / pregnant woman numerical model (adult Japanese average figure)
Sample size
—
Exposure
RF whole-body exposure
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: unknown

Main findings

A whole-body pregnant woman voxel model was developed by combining an adult Japanese female model with a new fetus model constructed from abdominal MRI data of a 7-month pregnant woman. Anatomical details of the model and basic SAR characteristics for whole-body RF exposure are presented.

Outcomes measured

  • Numerical dosimetry
  • Specific absorption rate (SAR) characteristics
  • Development of anatomically realistic voxel model

Limitations

  • No RF exposure parameters (e.g., frequency, field strength, duration) reported in the abstract
  • Sample size and representativeness of MRI source data not specified
  • Results described as 'basic SAR characteristics' without quantitative values in the abstract

Suggested hubs

  • exposure-assessment (0.9)
    Development of a numerical voxel model and SAR dosimetry for RF whole-body exposure in pregnancy.
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": "RF",
        "source": "whole-body exposure",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": "7-month pregnant woman (abdominal MRI data) / pregnant woman numerical model (adult Japanese average figure)",
    "sample_size": null,
    "outcomes": [
        "Numerical dosimetry",
        "Specific absorption rate (SAR) characteristics",
        "Development of anatomically realistic voxel model"
    ],
    "main_findings": "A whole-body pregnant woman voxel model was developed by combining an adult Japanese female model with a new fetus model constructed from abdominal MRI data of a 7-month pregnant woman. Anatomical details of the model and basic SAR characteristics for whole-body RF exposure are presented.",
    "effect_direction": "unclear",
    "limitations": [
        "No RF exposure parameters (e.g., frequency, field strength, duration) reported in the abstract",
        "Sample size and representativeness of MRI source data not specified",
        "Results described as 'basic SAR characteristics' without quantitative values in the abstract"
    ],
    "evidence_strength": "insufficient",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "unknown",
    "keywords": [
        "pregnancy",
        "fetus model",
        "voxel model",
        "MRI",
        "numerical dosimetry",
        "RF electromagnetic fields",
        "SAR",
        "whole-body exposure"
    ],
    "suggested_hubs": [
        {
            "slug": "exposure-assessment",
            "weight": 0.90000000000000002220446049250313080847263336181640625,
            "reason": "Development of a numerical voxel model and SAR dosimetry for RF whole-body exposure in pregnancy."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.