Effect of marination in gravy on the radio frequency and microwave processing properties of beef.
Abstract
Dielectric properties (the dielectric constant (ε') and the dielectric loss factor (ε″)) and the penetration depth of raw eye of round beef Semitendinosus muscle, raw beef marinated in gravy, raw beef cooked in gravy, and gravy alone were determined as a function of the temperature (20-130 °C) and frequency (27-1,800 MHz). Both ε' and ε″ values increased as the temperature increased at low frequencies (27 and 40 MHz). At high frequencies (915 and 1,800 MHz), ε' showed a 50 % decrease while ε″ increased nearly three fold with increasing temperature in the range from 20 to 130 °C. ε' increased gradually while ε″ increased five fold when the temperature increased from 20 to 130 °C. Both ε' and ε″ of all samples decreased with increase in frequency. Marinating the beef in gravy dramatically increased the ε″ values, particularly at the lower frequencies. Power penetration depth of all samples decreased with increase temperature and frequency. These results are expected to provide useful data for modeling dielectric heating processes of marinated muscle food.
AI evidence extraction
Main findings
Dielectric properties and penetration depth were measured for raw beef, beef marinated in gravy, beef cooked in gravy, and gravy across 27–1,800 MHz and 20–130 °C. ε' and ε″ generally decreased with increasing frequency; temperature effects differed by frequency (e.g., at 915 and 1,800 MHz ε' decreased while ε″ increased with temperature). Marination in gravy increased ε″, especially at lower frequencies, and penetration depth decreased with increasing temperature and frequency.
Outcomes measured
- Dielectric constant (ε')
- Dielectric loss factor (ε″)
- Power penetration depth
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": "RF",
"source": "microwave processing/dielectric heating",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"Dielectric constant (ε')",
"Dielectric loss factor (ε″)",
"Power penetration depth"
],
"main_findings": "Dielectric properties and penetration depth were measured for raw beef, beef marinated in gravy, beef cooked in gravy, and gravy across 27–1,800 MHz and 20–130 °C. ε' and ε″ generally decreased with increasing frequency; temperature effects differed by frequency (e.g., at 915 and 1,800 MHz ε' decreased while ε″ increased with temperature). Marination in gravy increased ε″, especially at lower frequencies, and penetration depth decreased with increasing temperature and frequency.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"dielectric properties",
"dielectric constant",
"dielectric loss factor",
"penetration depth",
"beef",
"marination",
"gravy",
"radio frequency",
"microwave",
"dielectric heating",
"915 MHz",
"1800 MHz"
],
"suggested_hubs": []
}
AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.