Assessment of combined exposure to intermediate-frequency electromagnetic fields and pulsed electromagnetic fields among library workers in Japan Yamaguchi-Sekino S, Taki M, Ikuyo M, Esaki K, Aimoto A, Wake K, Kojimahara N. Assessment of combined exposure to intermediate-frequency electromagnetic fields and pulsed electromagnetic fields among library workers in Japan. Front Public Health. 2022 Jul 28;10:870784. doi: 10.3389/fpubh.2022.870784. Abstract Objective: To assess exposure levels to electromagnetic fields (EMFs) among library workers in Japan, focusing on co-exposure to intermediate-frequency EMF (IF-EMF) and pulsed EMF, to propose a new epidemiological research methodology. Methods: The evaluated exposure sources were an electromagnetic type-electronic article surveillance gate (EM-EAS, IF-EMF (operating frequency 220 Hz-14 kHz)) and an activator/deactivator of anti-theft tags termed as "book check unit" (BCU, pulsed EMF). Short-term exposures were: (E1) whole-body exposure from the EAS gate when sitting within 3 m; (E2) local exposure to transient IF-EMF while passing through or beside the EAS gate; and (E3) local exposure to a pulsed magnetic field on BCU use. E1-E3 were evaluated based on exposure levels relative to magnetic flux density at the occupational reference level (RL; E1) or as per occupational basic restrictions (BR; E2 and E3) delineated by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) 2010 guidelines. Exposure indices based on mid-term exposure (D1-D3), assuming exposure according to employment on a weekly basis, were used to assess exposure in actual working conditions. D1 represents continuous exposure from an EAS gate when sitting within 3 m of the gate. D2 and D3 represent repeated transient exposures occurring during gate pass or on the operation of a BCU. A link to a web-based questionnaire was distributed to librarians working at all libraries where the authors had mailed institutional questionnaires (4,073 libraries). Four exposure patterns were defined according to various exposure scenarios. Results: We obtained information on exposure parameters and working conditions from the 548 completed questionnaires. The ICNIRP guideline levels were not exceeded in any of the E1-E3 scenarios. Median of the D1 (% ICNIRP RL × hour/week) was 1, and >85% respondents had values <10. However, the maximum value was 513. Altogether, these results indicate that continuous exposure was low in most cases. The same tendency was observed regarding repeated transient exposure from EM-EAS gates (i.e., the median value for D2 (% ICNIRP BR × gate pass) was 5). However, there were several cases in which D1 and D2 values were >10 times the median. The median of D3 (% ICNIRP BR × BCU operation) was 10, and most respondents' D3 values were greater than their D2 values, although the derived results depended on the assumptions made for the estimation. Conclusion: We conducted an assessment of combined exposures to IF-EMF and pulsed EMF among library workers in Japan by evaluating both short-term exposures (E1-E3) and exposure indices based on mid-term exposures (D1-D3) assuming actual working conditions per questionnaire results. These results provide useful information for future epidemiological studies. Open access paper: frontiersin.org

AI evidence extraction

At a glance
Study type
Exposure assessment
Effect direction
no_effect
Population
Library workers (librarians) in Japan
Sample size
548
Exposure
IF occupational · Short-term scenarios (E1-E3) and mid-term/weekly indices (D1-D3) based on questionnaire-assumed working conditions
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Across evaluated short-term scenarios (E1–E3), ICNIRP 2010 occupational guideline levels were not exceeded. For mid-term indices, median D1 was 1 (% ICNIRP RL × hour/week) with >85% of respondents <10, though the maximum D1 was 513; median D2 was 5 (% ICNIRP BR × gate pass) with some cases >10× the median. Median D3 was 10 (% ICNIRP BR × BCU operation), and most respondents’ D3 values were greater than their D2 values, with results depending on estimation assumptions.

Outcomes measured

  • Exposure levels to intermediate-frequency EMF (IF-EMF) from electromagnetic type electronic article surveillance (EM-EAS) gates (220 Hz–14 kHz)
  • Exposure levels to pulsed EMF from activator/deactivator (“book check unit”, BCU)
  • Exposure indices relative to ICNIRP 2010 occupational reference levels (RL) and basic restrictions (BR) for scenarios E1–E3 and indices D1–D3

Limitations

  • Exposure indices (D1–D3) were estimated using assumptions about weekly work patterns and exposure frequency/duration based on questionnaire results
  • Derived results for D3 were noted to depend on the assumptions made for estimation
  • Working-condition data were obtained from completed questionnaires (548 responses) from a larger distribution (4,073 libraries), implying potential response/selection limitations (not further detailed in abstract)

Suggested hubs

  • occupational-exposure (0.95)
    Assesses EMF exposure among library workers in workplace settings.
  • who-icnirp (0.7)
    Exposure evaluation explicitly referenced ICNIRP 2010 occupational reference levels and basic restrictions.
View raw extracted JSON
{
    "study_type": "exposure_assessment",
    "exposure": {
        "band": "IF",
        "source": "occupational",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "Short-term scenarios (E1-E3) and mid-term/weekly indices (D1-D3) based on questionnaire-assumed working conditions"
    },
    "population": "Library workers (librarians) in Japan",
    "sample_size": 548,
    "outcomes": [
        "Exposure levels to intermediate-frequency EMF (IF-EMF) from electromagnetic type electronic article surveillance (EM-EAS) gates (220 Hz–14 kHz)",
        "Exposure levels to pulsed EMF from activator/deactivator (“book check unit”, BCU)",
        "Exposure indices relative to ICNIRP 2010 occupational reference levels (RL) and basic restrictions (BR) for scenarios E1–E3 and indices D1–D3"
    ],
    "main_findings": "Across evaluated short-term scenarios (E1–E3), ICNIRP 2010 occupational guideline levels were not exceeded. For mid-term indices, median D1 was 1 (% ICNIRP RL × hour/week) with >85% of respondents <10, though the maximum D1 was 513; median D2 was 5 (% ICNIRP BR × gate pass) with some cases >10× the median. Median D3 was 10 (% ICNIRP BR × BCU operation), and most respondents’ D3 values were greater than their D2 values, with results depending on estimation assumptions.",
    "effect_direction": "no_effect",
    "limitations": [
        "Exposure indices (D1–D3) were estimated using assumptions about weekly work patterns and exposure frequency/duration based on questionnaire results",
        "Derived results for D3 were noted to depend on the assumptions made for estimation",
        "Working-condition data were obtained from completed questionnaires (548 responses) from a larger distribution (4,073 libraries), implying potential response/selection limitations (not further detailed in abstract)"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "intermediate-frequency EMF",
        "pulsed EMF",
        "occupational exposure",
        "library workers",
        "electronic article surveillance",
        "anti-theft gate",
        "book check unit",
        "ICNIRP 2010",
        "magnetic flux density",
        "questionnaire"
    ],
    "suggested_hubs": [
        {
            "slug": "occupational-exposure",
            "weight": 0.9499999999999999555910790149937383830547332763671875,
            "reason": "Assesses EMF exposure among library workers in workplace settings."
        },
        {
            "slug": "who-icnirp",
            "weight": 0.6999999999999999555910790149937383830547332763671875,