24h Extremely Low Frequency Electromagnetic Field Exposure Modulates Immune Responses in Rats

PAPER manual WSEAS TRANSACTIONS on BIOLOGY and BIOMEDICINE 2026 Animal study Effect: unclear Evidence: Low

Abstract

We examined the immune response induced by 24-hour continuous exposure to an ultra-low-frequency electromagnetic field (EMF) in white rats. We placed the experimental group wild-type albino rats in a special coil generating an electromagnetic field of 2 mT at a frequency of 50 Hz for 24 hours. The results of the study demonstrate that after 24 hours of continuous exposure to electromagnetic field, a significant increase in plasma potassium concentrations collected from the rats' tail veins was recorded (from 5.49 ± 0.46 to 13.07 ± 3.05 mmol/L). At the same time, the percentage of basophils in the blood increased significantly from 0.50 ± 0.09 to 1.03 ± 0.10%, while the platelet concentration decreased from 617.8 ± 15.2 × 10⁹/L to 323.5 ± 114.5 × 10⁹/L. The high standard deviation of immune system biomarkers allows us to conclude that the body responds through the involvement of individual mechanisms.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
unclear
Population
Wild-type albino rats
Sample size
—
Exposure
ELF Laboratory coil generating a 2 mT electromagnetic field · 5.0E-5 MHz · 24 hours of continuous exposure
Evidence strength
Low
Confidence: 95% · Peer-reviewed: yes

Main findings

Following exposure, plasma potassium increased significantly from 5.49 ± 0.46 to 13.07 ± 3.05 mmol/L, and blood basophils increased significantly from 0.50 ± 0.09% to 1.03 ± 0.10%. Platelet concentration decreased from 617.8 ± 15.2 × 10⁹/L to 323.5 ± 114.5 × 10⁹/L.

Outcomes measured

  • Plasma potassium concentration
  • Blood basophil percentage
  • Platelet concentration

Limitations

  • Sample size is not reported in the abstract.
  • Control-group conditions, randomization, and blinding are not described in the abstract.
  • High variability in immune-system biomarkers is acknowledged by the authors.
  • Only a single exposure duration and field setting are described.
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "ELF",
        "source": "Laboratory coil generating a 2 mT electromagnetic field",
        "frequency_mhz": 5.00000000000000023960868011929647991564706899225711822509765625e-5,
        "sar_wkg": null,
        "duration": "24 hours of continuous exposure"
    },
    "population": "Wild-type albino rats",
    "sample_size": null,
    "outcomes": [
        "Plasma potassium concentration",
        "Blood basophil percentage",
        "Platelet concentration"
    ],
    "main_findings": "Following exposure, plasma potassium increased significantly from 5.49 ± 0.46 to 13.07 ± 3.05 mmol/L, and blood basophils increased significantly from 0.50 ± 0.09% to 1.03 ± 0.10%. Platelet concentration decreased from 617.8 ± 15.2 × 10⁹/L to 323.5 ± 114.5 × 10⁹/L.",
    "effect_direction": "unclear",
    "limitations": [
        "Sample size is not reported in the abstract.",
        "Control-group conditions, randomization, and blinding are not described in the abstract.",
        "High variability in immune-system biomarkers is acknowledged by the authors.",
        "Only a single exposure duration and field setting are described."
    ],
    "evidence_strength": "low",
    "confidence": 0.9499999999999999555910790149937383830547332763671875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "extremely low frequency",
        "ELF-EMF",
        "50 Hz",
        "2 mT",
        "rats",
        "immune response",
        "plasma potassium",
        "basophils",
        "platelets",
        "24-hour exposure"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.