Share
𝕏 Facebook LinkedIn

In vivo genotoxicity of high-intensity intermediate frequency magnetic fields in somatic cells and germ cells

PAPER manual Journal of radiation research 2022 Animal study Effect: no_effect Evidence: Low

Abstract

In vivo genotoxicity of high-intensity intermediate frequency magnetic fields in somatic cells and germ cells Ohtani S, Ushiyama A, Wada K, Suzuki Y, Hattori K. In vivo genotoxicity of high-intensity intermediate frequency magnetic fields in somatic cells and germ cells. J Radiat Res. 2022 Dec 29:rrac081. doi: 10.1093/jrr/rrac081. Abstract Intermediate frequency magnetic fields (IF-MFs) at ~85 kHz are one of the components of wireless power transfer (WPT) systems. However, the available data needed for the assessment of the safety of organisms from IF-MF exposure are scarce. Thus, there is an imminent need to accumulate evidence-based assessment data. In particular, if humans are exposed to IF-MF due to an accident or trouble, they are at increased risk of being exposed to high-intensity IF-MF within a short period. The already existing exposure system was improved to a system that could intermittently expose animals at 3 s intervals. This system allows the exposure of a mouse to high-intensity IF-MF (frequency: 82.3 kHz; induced electric field: 87 V/m, which was 3.8 times the basic restriction level for occupational exposure in the ICNIRP guideline), while regulating the heat generated by the coil. In vivo genotoxicity after IF-MF exposure was assessed using micronucleus (MN) test, Pig-a assay, and gpt assay. The results of MN test and Pig-a assay in hematopoietic cells revealed that neither the reticulocytes nor the mature erythrocytes exhibited significant increases in the IF-MF-exposed group compared with that in the sham-exposed group. In germ cells, MN test and gpt assay outcomes showed that IF-MF exposure did not cause any genetic or chromosomal abnormality. Based on these data, there was no genotoxic effect of our set IF-MF exposure on somatic and germ cells. These findings can contribute to the widespread use of WPT systems as effective data of IF-MF safety assessment. pubmed.ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
no_effect
Population
Mouse
Sample size
—
Exposure
intermediate frequency wireless power transfer (WPT) systems · 0.0823 MHz · intermittent exposure at 3 s intervals
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

In hematopoietic cells, micronucleus and Pig-a assay results showed no significant increases in reticulocytes or mature erythrocytes in IF-MF-exposed mice versus sham. In germ cells, micronucleus and gpt assay outcomes indicated no genetic or chromosomal abnormalities; overall, no genotoxic effect was observed under the described IF-MF exposure conditions.

Outcomes measured

  • Genotoxicity in hematopoietic cells (micronucleus test)
  • Mutagenicity in hematopoietic cells (Pig-a assay)
  • Genotoxicity/mutagenicity in germ cells (micronucleus test, gpt assay)

Limitations

  • Sample size not reported in abstract
  • Exposure duration/total exposure time not specified in abstract
  • Only genotoxicity endpoints assessed (MN, Pig-a, gpt); other health outcomes not addressed

Suggested hubs

  • who-icnirp (0.6)
    Exposure level is explicitly compared to the ICNIRP basic restriction level for occupational exposure.
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "intermediate frequency",
        "source": "wireless power transfer (WPT) systems",
        "frequency_mhz": 0.08229999999999999815702977912224014289677143096923828125,
        "sar_wkg": null,
        "duration": "intermittent exposure at 3 s intervals"
    },
    "population": "Mouse",
    "sample_size": null,
    "outcomes": [
        "Genotoxicity in hematopoietic cells (micronucleus test)",
        "Mutagenicity in hematopoietic cells (Pig-a assay)",
        "Genotoxicity/mutagenicity in germ cells (micronucleus test, gpt assay)"
    ],
    "main_findings": "In hematopoietic cells, micronucleus and Pig-a assay results showed no significant increases in reticulocytes or mature erythrocytes in IF-MF-exposed mice versus sham. In germ cells, micronucleus and gpt assay outcomes indicated no genetic or chromosomal abnormalities; overall, no genotoxic effect was observed under the described IF-MF exposure conditions.",
    "effect_direction": "no_effect",
    "limitations": [
        "Sample size not reported in abstract",
        "Exposure duration/total exposure time not specified in abstract",
        "Only genotoxicity endpoints assessed (MN, Pig-a, gpt); other health outcomes not addressed"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "intermediate frequency magnetic fields",
        "IF-MF",
        "wireless power transfer",
        "WPT",
        "82.3 kHz",
        "induced electric field",
        "ICNIRP",
        "occupational exposure",
        "micronucleus test",
        "Pig-a assay",
        "gpt assay",
        "genotoxicity",
        "germ cells",
        "somatic cells",
        "mouse"
    ],
    "suggested_hubs": [
        {
            "slug": "who-icnirp",
            "weight": 0.59999999999999997779553950749686919152736663818359375,
            "reason": "Exposure level is explicitly compared to the ICNIRP basic restriction level for occupational exposure."
        }
    ]
}