Modelling and Evaluation of the Absorption of the 866 MHz Electromagnetic Field in Humans Exposed near to Fixed I-RFID Readers Used in Medical RTLS or to Monitor PPE.

PAPER pubmed Sensors (Basel, Switzerland) 2021 Engineering / measurement Effect: unclear Evidence: Insufficient

Abstract

The aim of this study was to model and evaluate the Specific Energy Absorption Rate (SAR) values in humans in proximity to fixed multi-antenna I-RFID readers of passive tags under various scenarios mimicking exposure when they are incorporated in Real-Time Location Systems (RTLS), or used to monitor Personal Protective Equipment (PPE). The sources of the electromagnetic field (EMF) in the modelled readers were rectangular microstrip antennas at a resonance frequency in free space of 866 MHz from the ultra-high frequency (UHF) RFID frequency range of 865-868 MHz. The obtained results of numerical modelling showed that the SAR values in the body 5 cm away from the UHF RFID readers need consideration with respect to exposure limits set by international guidelines to prevent adverse thermal effects of exposure to EMF: when the effective radiated power exceeds 5.5 W with respect to the general public/unrestricted environments exposure limits, and with respect to occupational/restricted environments exposure limits, when the effective radiated power exceeds 27.5 W.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
unclear
Population
Humans (modelled)
Sample size
—
Exposure
RF I-RFID reader (UHF RFID) · 866 MHz
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

Numerical modelling of exposure near fixed multi-antenna UHF RFID readers (866 MHz) indicated that SAR values at 5 cm distance warrant consideration relative to international exposure limits. The study reports that effective radiated power above 5.5 W may exceed general public/unrestricted environment limits, and above 27.5 W may exceed occupational/restricted environment limits.

Outcomes measured

  • Specific Energy Absorption Rate (SAR) in humans near fixed multi-antenna I-RFID readers
  • Comparison to international exposure limits/guidelines for preventing adverse thermal effects

Limitations

  • Numerical modelling study (no direct measurements in humans reported in abstract)
  • Exposure scenarios limited to proximity (5 cm) and modelled reader/antenna configurations described

Suggested hubs

  • occupational-exposure (0.62)
    Abstract explicitly compares modelled exposure to occupational/restricted environment exposure limits.
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": "RF",
        "source": "I-RFID reader (UHF RFID)",
        "frequency_mhz": 866,
        "sar_wkg": null,
        "duration": null
    },
    "population": "Humans (modelled)",
    "sample_size": null,
    "outcomes": [
        "Specific Energy Absorption Rate (SAR) in humans near fixed multi-antenna I-RFID readers",
        "Comparison to international exposure limits/guidelines for preventing adverse thermal effects"
    ],
    "main_findings": "Numerical modelling of exposure near fixed multi-antenna UHF RFID readers (866 MHz) indicated that SAR values at 5 cm distance warrant consideration relative to international exposure limits. The study reports that effective radiated power above 5.5 W may exceed general public/unrestricted environment limits, and above 27.5 W may exceed occupational/restricted environment limits.",
    "effect_direction": "unclear",
    "limitations": [
        "Numerical modelling study (no direct measurements in humans reported in abstract)",
        "Exposure scenarios limited to proximity (5 cm) and modelled reader/antenna configurations described"
    ],
    "evidence_strength": "insufficient",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "SAR",
        "specific energy absorption rate",
        "UHF RFID",
        "I-RFID",
        "866 MHz",
        "865-868 MHz",
        "microstrip antenna",
        "RTLS",
        "personal protective equipment",
        "occupational exposure",
        "exposure limits",
        "international guidelines"
    ],
    "suggested_hubs": [
        {
            "slug": "occupational-exposure",
            "weight": 0.61999999999999999555910790149937383830547332763671875,
            "reason": "Abstract explicitly compares modelled exposure to occupational/restricted environment exposure limits."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.