Share
𝕏 Facebook LinkedIn

No effects of 900 MHz and 1800 MHz electromagnetic field emitted from cellular phone on nocturnal serum melatonin levels in rats.

PAPER pubmed Toxicology and industrial health 2005 Animal study Effect: no_effect Evidence: Low

Abstract

In this study, the effects of exposure to a 900 MHz and 1800 MHz electromagnetic field (EMF) on serum nocturnal melatonin levels of adult male Sprague-Dawley rats were studied. Thirty rats were used in three independent groups, 10 of which were exposed to 900 MHz, 10 of which were exposed to 1800 MHz and 10 of which were sham-exposed (control). The exposures were performed 30 min/day, for five days/week for four weeks to 900 MHz or 1800 MHz EMF Control animals were kept under the same environmental conditions as the study groups except with no EMF exposure. The concentration of nocturnal melatonin in the rat serum was measured by using a radioimmunoassay method. There were no statistically significant differences in serum melatonin concentrations between the 900 MHz EMF group and the sham-exposed group (P > 0.05). The values at 12:00 pm were 39.11 +/- 6.5 pg/mL in the sham-exposed group and 34.97 +/- 5.1 pg/mL in the 900 MHz EMF-exposed group. Also, there were no statistically significant differences in serum melatonin concentrations between the sham-exposed group and the 1800 MHz EMF-exposed group (P > 0.05). The values at 12:00 pm were 39.11 +/- 6.5 pg/mL in the sham-exposed group and 37.96 +/- 7.4 pg/mL in the exposed group. These results indicate that mobile phones, emitting 900 and 1800 MHz EMF, have no effect on nocturnal serum melatonin levels in rats.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
no_effect
Population
Adult male Sprague-Dawley rats
Sample size
30
Exposure
RF mobile phone · 30 min/day, 5 days/week for 4 weeks
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Thirty rats were assigned to 900 MHz exposure, 1800 MHz exposure, or sham exposure (10 per group). No statistically significant differences in nocturnal serum melatonin concentrations were observed between either exposure group and sham (P > 0.05).

Outcomes measured

  • Nocturnal serum melatonin concentration (radioimmunoassay)

Limitations

  • SAR or exposure intensity not reported in abstract
  • Only adult male rats studied
  • Short exposure duration (4 weeks)
  • Single biomarker outcome (serum nocturnal melatonin) reported

Suggested hubs

  • mobile-phones-rf (0.9)
    Study tests 900/1800 MHz EMF emitted from cellular phones in an animal model.
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "RF",
        "source": "mobile phone",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "30 min/day, 5 days/week for 4 weeks"
    },
    "population": "Adult male Sprague-Dawley rats",
    "sample_size": 30,
    "outcomes": [
        "Nocturnal serum melatonin concentration (radioimmunoassay)"
    ],
    "main_findings": "Thirty rats were assigned to 900 MHz exposure, 1800 MHz exposure, or sham exposure (10 per group). No statistically significant differences in nocturnal serum melatonin concentrations were observed between either exposure group and sham (P > 0.05).",
    "effect_direction": "no_effect",
    "limitations": [
        "SAR or exposure intensity not reported in abstract",
        "Only adult male rats studied",
        "Short exposure duration (4 weeks)",
        "Single biomarker outcome (serum nocturnal melatonin) reported"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "900 MHz",
        "1800 MHz",
        "RF-EMF",
        "mobile phone",
        "rats",
        "Sprague-Dawley",
        "melatonin",
        "nocturnal serum",
        "radioimmunoassay",
        "sham-exposed"
    ],
    "suggested_hubs": [
        {
            "slug": "mobile-phones-rf",
            "weight": 0.90000000000000002220446049250313080847263336181640625,
            "reason": "Study tests 900/1800 MHz EMF emitted from cellular phones in an animal model."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.