Share
𝕏 Facebook LinkedIn

Effects of low level electromagnetic field exposure at 2.45 GHz on rat cornea.

PAPER pubmed International journal of radiation biology 2013 Animal study Effect: mixed Evidence: Low

Abstract

PURPOSE: To investigate the effects of low level electromagnetic field (low level-EMF) exposure, as frequently encountered in daily life, on the normal rat cornea using histological and stereological method. METHODS: Twenty-two adult male Wistar rats were randomly divided into two groups: Study group (n = 11) and control group (n = 11). Rats in the study group were exposed to 2.45 GHz microwave (MW) radiation (11.96 ± 0.89 V/m), 0.25 W/kg specific absorption rate (SAR) for 2 hours each day for 21 days. The corneal thickness and the anterior epithelium corneal thickness were measured using two different methods. RESULTS: Using the histological method, the mean corneal thicknesses in the control and study group were 278.9 ± 54.5 μm, and 272.4 ± 85.6 μm, respectively. There was no statistically significant difference between the groups (p > 0.05). The anterior corneal epithelium thickness was 28.1 ± 4.9 μm in the control group and 31.7 ± 5.5 μm in the study group. There were statistically differences between the groups with regard to the thickness of anterior epithelium (p < 0.05). In the measurement made by the stereological method, the percentage of the cornea occupied by anterior corneal epithelium was 15.94% in the control group and 17.9% in the study group. Despite the fact that there was a relation between increased anterior epithelial area (AEA) and radiation exposure, no statistically significant relationship in area fraction of each compartment was found between the control and study groups. CONCLUSIONS: Results of this preliminary study show that exposure to MW radiation might cause alterations in the rat cornea.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Adult male Wistar rats
Sample size
22
Exposure
microwave · 2450 MHz · 0.25 W/kg · 2 hours/day for 21 days
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Rats exposed to 2.45 GHz microwave radiation (11.96 ± 0.89 V/m; SAR 0.25 W/kg) showed no statistically significant difference in mean corneal thickness versus controls (p > 0.05). Anterior corneal epithelium thickness was higher in the exposed group than controls by histological measurement (p < 0.05), while stereological assessment found no statistically significant differences in area fractions of corneal compartments.

Outcomes measured

  • Corneal thickness
  • Anterior corneal epithelium thickness
  • Percentage of cornea occupied by anterior corneal epithelium (area fraction/AEA)

Limitations

  • Described as a preliminary study
  • Small sample size (n=11 per group)
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "microwave",
        "source": null,
        "frequency_mhz": 2450,
        "sar_wkg": 0.25,
        "duration": "2 hours/day for 21 days"
    },
    "population": "Adult male Wistar rats",
    "sample_size": 22,
    "outcomes": [
        "Corneal thickness",
        "Anterior corneal epithelium thickness",
        "Percentage of cornea occupied by anterior corneal epithelium (area fraction/AEA)"
    ],
    "main_findings": "Rats exposed to 2.45 GHz microwave radiation (11.96 ± 0.89 V/m; SAR 0.25 W/kg) showed no statistically significant difference in mean corneal thickness versus controls (p > 0.05). Anterior corneal epithelium thickness was higher in the exposed group than controls by histological measurement (p < 0.05), while stereological assessment found no statistically significant differences in area fractions of corneal compartments.",
    "effect_direction": "mixed",
    "limitations": [
        "Described as a preliminary study",
        "Small sample size (n=11 per group)"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "2.45 GHz",
        "microwave radiation",
        "low level EMF",
        "SAR",
        "rat",
        "cornea",
        "histology",
        "stereology",
        "corneal thickness",
        "anterior epithelium"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.