Share
𝕏 Facebook LinkedIn

A 1-μT extremely low-frequency electromagnetic field vs. sham control for mild-to-moderate hypertension: a double-blind, randomized study.

PAPER pubmed Hypertension research : official journal of the Japanese Society of Hypertension 2011 Randomized trial Effect: benefit Evidence: Low

Abstract

The effects of extremely low-frequency electromagnetic fields (ELF-EMFs) on blood pressure (BP) are controversial. In this double-blind, randomized, sham-controlled study, we examined the effects of repeated exposure to a 1-μT ELF-EMF on BP in 20 humans with mild-to-moderate hypertension. Subjects were randomly assigned to either the ELF-EMF group or the sham group. Subjects in the ELF-EMF group were exposed to an ELF-EMF (6- and 8 Hz, respectively, peak magnetic field 1 μT, peak electric field 10 Vm(-1)) for at least two 10- to 15-min sessions per week, over a period of 4 weeks. In the sham group, the EMF-generating apparatus was not active. We obtained systolic and diastolic BP (SBP and DBP, respectively) measurements at registration and before and after each ELF-EMF exposure session. Subjects in the ELF-EMF and sham groups had mean ages of 52.8 and 55.1 years, and were exposed to a mean of 9.9 and 9.0 sessions, respectively. There was a significant difference between the ELF-EMF and sham groups with respect to change in SBP value between baseline and the end of the exposure regimen (P=0.02), but not with respect to change in DBP (P=0.21). There were no adverse events other than mild paresthesia of the hands of two subjects in the ELF-EMF group. Our results suggest that repeated exposure to an ELF-EMF has a BP-lowering effect on humans with mild-to-moderate hypertension.

AI evidence extraction

At a glance
Study type
Randomized trial
Effect direction
benefit
Population
Humans with mild-to-moderate hypertension
Sample size
20
Exposure
ELF other · At least two 10–15 min sessions per week for 4 weeks (mean 9.9 sessions in ELF-EMF group; 9.0 in sham)
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Compared with sham, the ELF-EMF group showed a significant difference in change in systolic blood pressure from baseline to end of the 4-week regimen (P=0.02), but not in diastolic blood pressure (P=0.21). Two participants in the ELF-EMF group reported mild hand paresthesia; no other adverse events were reported.

Outcomes measured

  • Systolic blood pressure (SBP)
  • Diastolic blood pressure (DBP)
  • Adverse events (paresthesia)

Limitations

  • Small sample size (n=20)
  • Short intervention/follow-up period (4 weeks)

Suggested hubs

  • who-icnirp (0.2)
    Study concerns health effects of ELF electromagnetic field exposure, relevant to general EMF health guidance discussions.
View raw extracted JSON
{
    "study_type": "randomized_trial",
    "exposure": {
        "band": "ELF",
        "source": "other",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "At least two 10–15 min sessions per week for 4 weeks (mean 9.9 sessions in ELF-EMF group; 9.0 in sham)"
    },
    "population": "Humans with mild-to-moderate hypertension",
    "sample_size": 20,
    "outcomes": [
        "Systolic blood pressure (SBP)",
        "Diastolic blood pressure (DBP)",
        "Adverse events (paresthesia)"
    ],
    "main_findings": "Compared with sham, the ELF-EMF group showed a significant difference in change in systolic blood pressure from baseline to end of the 4-week regimen (P=0.02), but not in diastolic blood pressure (P=0.21). Two participants in the ELF-EMF group reported mild hand paresthesia; no other adverse events were reported.",
    "effect_direction": "benefit",
    "limitations": [
        "Small sample size (n=20)",
        "Short intervention/follow-up period (4 weeks)"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "extremely low-frequency electromagnetic fields",
        "ELF-EMF",
        "1 μT",
        "6 Hz",
        "8 Hz",
        "hypertension",
        "blood pressure",
        "double-blind",
        "randomized",
        "sham-controlled",
        "systolic blood pressure",
        "diastolic blood pressure",
        "paresthesia"
    ],
    "suggested_hubs": [
        {
            "slug": "who-icnirp",
            "weight": 0.200000000000000011102230246251565404236316680908203125,
            "reason": "Study concerns health effects of ELF electromagnetic field exposure, relevant to general EMF health guidance discussions."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.