Share
𝕏 Facebook LinkedIn

Oxidative stress, melatonin level, and sleep insufficiency among electronic equipment repairers.

PAPER pubmed Indian journal of occupational and environmental medicine 2010 Cross-sectional study Effect: mixed Evidence: Low

Abstract

BACKGROUND: Exposure to extremely low frequency electromagnetic field (ELF-EMF), especially among electronic equipment repairers may induce oxidative stress and affect sleep quality. AIMS: This study was carried out to (a) investigate the effect of exposure to ELF-EMF on the malondialdehyde (MDA) levels among electronic equipment repairers as an indicator of oxidative stress; and melatonin hormone levels; and (b) to study the prevalence of sleep insufficiency among electronic equipment repairers exposed to ELF-EMF. MATERIALS AND METHODS: A cross-sectional study was carried out on 50 electronic equipment repairers at high risk of exposure to ELF-EMF, and a matched control group at lower risk of exposure to ELF-EMF. All the participants completed a self-administered questionnaire about medical and occupational histories; and sleep sufficiency. The plasma melatonin and MDA levels of the study subjects were assessed. RESULTS: The mean level of serum melatonin in the electronic equipment repairers was lower than that of the controls (P < 0.01). Moreover, serum MDA mean level of the electronic equipment repairers was higher than that of the controls (P < 0.01). Sleep insufficiency was more frequent among electronic equipment repairers (18.00%) in comparison with the controls (8.70%) (P > 0.05) CONCLUSION: The electronic equipment repairers, exposed to ELF-EMF, are at a risk of oxidative stress and sleep insufficiency, which could be explained by lower plasma melatonin levels and higher MDA levels. Health education about the hazards of ELF-EMF, shortening of exposure time per day, and taking antioxidant vitamins should be done to ameliorate the oxidative effect of EMF on those workers.

AI evidence extraction

At a glance
Study type
Cross-sectional study
Effect direction
mixed
Population
Electronic equipment repairers (high risk of ELF-EMF exposure) and matched controls (lower risk)
Sample size
50
Exposure
ELF occupational
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Compared with matched controls, electronic equipment repairers had lower mean serum melatonin (P < 0.01) and higher mean serum MDA (P < 0.01). Sleep insufficiency was more frequent among repairers (18.0%) than controls (8.7%), but this difference was not statistically significant (P > 0.05).

Outcomes measured

  • Malondialdehyde (MDA) levels (oxidative stress marker)
  • Melatonin levels
  • Sleep insufficiency prevalence

Limitations

  • Cross-sectional design
  • Exposure described as high vs lower risk; no quantitative ELF-EMF measurements reported in abstract
  • Sleep insufficiency assessed by self-administered questionnaire

Suggested hubs

  • occupational-exposure (0.9)
    Study population is workers (electronic equipment repairers) with presumed higher occupational ELF-EMF exposure compared with controls.
View raw extracted JSON
{
    "study_type": "cross_sectional",
    "exposure": {
        "band": "ELF",
        "source": "occupational",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": "Electronic equipment repairers (high risk of ELF-EMF exposure) and matched controls (lower risk)",
    "sample_size": 50,
    "outcomes": [
        "Malondialdehyde (MDA) levels (oxidative stress marker)",
        "Melatonin levels",
        "Sleep insufficiency prevalence"
    ],
    "main_findings": "Compared with matched controls, electronic equipment repairers had lower mean serum melatonin (P < 0.01) and higher mean serum MDA (P < 0.01). Sleep insufficiency was more frequent among repairers (18.0%) than controls (8.7%), but this difference was not statistically significant (P > 0.05).",
    "effect_direction": "mixed",
    "limitations": [
        "Cross-sectional design",
        "Exposure described as high vs lower risk; no quantitative ELF-EMF measurements reported in abstract",
        "Sleep insufficiency assessed by self-administered questionnaire"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "ELF-EMF",
        "occupational exposure",
        "electronic equipment repairers",
        "oxidative stress",
        "malondialdehyde",
        "melatonin",
        "sleep insufficiency"
    ],
    "suggested_hubs": [
        {
            "slug": "occupational-exposure",
            "weight": 0.90000000000000002220446049250313080847263336181640625,
            "reason": "Study population is workers (electronic equipment repairers) with presumed higher occupational ELF-EMF exposure compared with controls."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.