Share
𝕏 Facebook LinkedIn

Magnetic field effects-polarization-resonant synchronous fluorescence spectrometry for simultaneous analysis of polynuclear aromatic hydrocarbons in mixtures.

PAPER pubmed Talanta 1995 Engineering / measurement Effect: unclear Evidence: Insufficient

Abstract

The level and undulation of scattered light can be effectively suppressed by magnetic field effects-polarization-resonant synchronous fluorescence spectrometry. The established technique was used for simultaneous determination of a sample mixture containing fluorene, acenaphthene, anthracene, benzo-[a]-pyrene (B-[a]-P) and perylene. The detection limits were 0.23, 7.90, 0.13, 1.10, 0.0083 ng ml(-1) for fluorene, acenaphthene, anthracene, B-[a]-P and perylene, respectively. The relative standard deviations were less than 5%.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
unclear
Population
—
Sample size
—
Exposure
magnetic field (instrumental/analytical method)
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

Magnetic field effects–polarization–resonant synchronous fluorescence spectrometry was reported to effectively suppress the level and undulation of scattered light and was used for simultaneous determination of a mixture of five polynuclear aromatic hydrocarbons. Reported detection limits were 0.23, 7.90, 0.13, 1.10, and 0.0083 ng ml(-1) for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene, respectively, with relative standard deviations <5%.

Outcomes measured

  • Suppression of scattered light level and undulation in fluorescence spectrometry
  • Detection limits for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene
  • Relative standard deviation (precision)

Limitations

  • No biological or health outcomes assessed (analytical chemistry method).
  • Magnetic field parameters (strength, frequency) not reported in the abstract.
  • Sample type and number of measurements/replicates not stated.
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": null,
        "source": "magnetic field (instrumental/analytical method)",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Suppression of scattered light level and undulation in fluorescence spectrometry",
        "Detection limits for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene",
        "Relative standard deviation (precision)"
    ],
    "main_findings": "Magnetic field effects–polarization–resonant synchronous fluorescence spectrometry was reported to effectively suppress the level and undulation of scattered light and was used for simultaneous determination of a mixture of five polynuclear aromatic hydrocarbons. Reported detection limits were 0.23, 7.90, 0.13, 1.10, and 0.0083 ng ml(-1) for fluorene, acenaphthene, anthracene, benzo-[a]-pyrene, and perylene, respectively, with relative standard deviations <5%.",
    "effect_direction": "unclear",
    "limitations": [
        "No biological or health outcomes assessed (analytical chemistry method).",
        "Magnetic field parameters (strength, frequency) not reported in the abstract.",
        "Sample type and number of measurements/replicates not stated."
    ],
    "evidence_strength": "insufficient",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "magnetic field effects",
        "polarization",
        "resonant synchronous fluorescence spectrometry",
        "scattered light suppression",
        "polynuclear aromatic hydrocarbons",
        "fluorene",
        "acenaphthene",
        "anthracene",
        "benzo[a]pyrene",
        "perylene",
        "detection limit",
        "precision"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.