[The influence of pulsed magnetic fields on SOD's activity and MDA value in metabolism of mice].

PAPER pubmed Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi 1999 Animal study Effect: mixed Evidence: Low

Abstract

This experiment aimed to investigate the influence of pulsed extremely-low-frequency-magnetic fields on free radical metabolism of mice. Thirty-two mice were randomly divided into four groups and were exposed to 0 T, 0.25 T, 0.34 T and 0.64 T intensity pulsed magnetic fields of 20 Hz for 40 min. The 0 T exposed group was the control group. The free radical metabolism, SOD's activity and MDA, of mice were measured respectively. The result showed the SOD's activity and MDA of the 0.34 T exposed group were both significantly lower (P < 0.01, P < 0.05) than that of the control group, while the 0.25 T and 0.64 T exposed groups were not significantly different from the control group. This demonstrates that the biological effect of pulsed extremely-low-frequency magnetic fields on free radical metabolism of mice varies and depends on the intensity of the fields. The "window" effect may exist.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
mice
Sample size
32
Exposure
ELF pulsed magnetic fields · 40 min
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Thirty-two mice were exposed to 20 Hz pulsed magnetic fields at 0 T (control), 0.25 T, 0.34 T, or 0.64 T for 40 minutes. SOD activity and MDA were significantly lower in the 0.34 T group than in controls, while the 0.25 T and 0.64 T groups did not differ significantly from controls.

Outcomes measured

  • SOD activity
  • MDA value
  • free radical metabolism

Limitations

  • Only one exposure duration reported (40 min)
  • Findings differed by field intensity (only 0.34 T showed significant changes)
  • No additional methodological details provided in abstract (e.g., blinding, timing of outcome measurement)

Suggested hubs

  • occupational-exposure (0.2)
    Uses relatively high-intensity ELF magnetic fields; could be relevant to high-field exposure contexts, though no occupational setting is stated.
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "ELF",
        "source": "pulsed magnetic fields",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "40 min"
    },
    "population": "mice",
    "sample_size": 32,
    "outcomes": [
        "SOD activity",
        "MDA value",
        "free radical metabolism"
    ],
    "main_findings": "Thirty-two mice were exposed to 20 Hz pulsed magnetic fields at 0 T (control), 0.25 T, 0.34 T, or 0.64 T for 40 minutes. SOD activity and MDA were significantly lower in the 0.34 T group than in controls, while the 0.25 T and 0.64 T groups did not differ significantly from controls.",
    "effect_direction": "mixed",
    "limitations": [
        "Only one exposure duration reported (40 min)",
        "Findings differed by field intensity (only 0.34 T showed significant changes)",
        "No additional methodological details provided in abstract (e.g., blinding, timing of outcome measurement)"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "pulsed magnetic fields",
        "extremely low frequency",
        "20 Hz",
        "mice",
        "SOD",
        "superoxide dismutase",
        "MDA",
        "malondialdehyde",
        "free radicals",
        "window effect"
    ],
    "suggested_hubs": [
        {
            "slug": "occupational-exposure",
            "weight": 0.200000000000000011102230246251565404236316680908203125,
            "reason": "Uses relatively high-intensity ELF magnetic fields; could be relevant to high-field exposure contexts, though no occupational setting is stated."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.