[Risk of electromagnetic fields in control board and switchboard rooms at petrochemical plants].
Abstract
Authors evaluate electromagnetic field exposure (in the range (5-30,000 Hz) in control board and switchboard rooms of petrochemical plants. According to measured values and international guidelines, they conclude that operators should be exposed without adverse effects.
AI evidence extraction
At a glance
Study type
Exposure assessment
Effect direction
no_effect
Population
Operators in control board and switchboard rooms at petrochemical plants
Sample size
—
Exposure
ELF occupational
Evidence strength
Low
Confidence: 72%
· Peer-reviewed: yes
Main findings
Electromagnetic field exposure was evaluated in control board and switchboard rooms at petrochemical plants across 5–30,000 Hz. Based on measured values and comparison with international guidelines, the authors conclude operators should be exposed without adverse effects.
Outcomes measured
- Measured electromagnetic field exposure levels (5–30,000 Hz)
- Assessment versus international guideline limits
- Conclusion regarding adverse effects risk
Limitations
- No sample size reported in abstract
- No quantitative exposure measurements provided in abstract
- Health outcomes were not directly measured; conclusion is based on comparison to guidelines
Suggested hubs
-
occupational-exposure
(0.9) Exposure assessment in workplace settings (petrochemical plant control/switchboard rooms).
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "ELF",
"source": "occupational",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Operators in control board and switchboard rooms at petrochemical plants",
"sample_size": null,
"outcomes": [
"Measured electromagnetic field exposure levels (5–30,000 Hz)",
"Assessment versus international guideline limits",
"Conclusion regarding adverse effects risk"
],
"main_findings": "Electromagnetic field exposure was evaluated in control board and switchboard rooms at petrochemical plants across 5–30,000 Hz. Based on measured values and comparison with international guidelines, the authors conclude operators should be exposed without adverse effects.",
"effect_direction": "no_effect",
"limitations": [
"No sample size reported in abstract",
"No quantitative exposure measurements provided in abstract",
"Health outcomes were not directly measured; conclusion is based on comparison to guidelines"
],
"evidence_strength": "low",
"confidence": 0.7199999999999999733546474089962430298328399658203125,
"peer_reviewed_likely": "yes",
"keywords": [
"electromagnetic fields",
"occupational exposure",
"petrochemical plants",
"control board rooms",
"switchboard rooms",
"guidelines",
"5-30000 Hz"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.90000000000000002220446049250313080847263336181640625,
"reason": "Exposure assessment in workplace settings (petrochemical plant control/switchboard rooms)."
}
]
}
AI can be wrong. Always verify against the paper.
AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect.
This content is for informational purposes only and is not medical advice.
Comments
Log in to comment.
No comments yet.