Correction of microcirculatory disturbances with terahertz electromagnetic radiation at nitric oxide frequencies in albino rats under conditions of acute stress.
Abstract
Terahertz electromagnetic irradiation at frequencies corresponding to NO molecular emission and absorption spectrum 150.176-150.664 GHz corrects disturbances in peripheral circulation typical of acute stress reaction in rats during acute immobilization stress.
AI evidence extraction
At a glance
Study type
Animal study
Effect direction
benefit
Population
Albino rats under acute immobilization stress
Sample size
—
Exposure
mmWave · 150420 MHz
Evidence strength
Low
Confidence: 66%
· Peer-reviewed: yes
Main findings
Terahertz electromagnetic irradiation at 150.176–150.664 GHz (frequencies corresponding to nitric oxide molecular emission/absorption) corrected disturbances in peripheral circulation typical of an acute stress reaction in rats during acute immobilization stress.
Outcomes measured
- Peripheral microcirculation/peripheral circulation disturbances during acute stress
Limitations
- No sample size reported in abstract
- Exposure duration and dosimetry (e.g., SAR) not reported in abstract
- Outcome measurement methods not described in abstract
Suggested hubs
-
mmwave-terahertz
(0.9) Animal study using terahertz/mmWave exposure (150 GHz range) with physiological outcomes.
View raw extracted JSON
{
"study_type": "animal",
"exposure": {
"band": "mmWave",
"source": null,
"frequency_mhz": 150420,
"sar_wkg": null,
"duration": null
},
"population": "Albino rats under acute immobilization stress",
"sample_size": null,
"outcomes": [
"Peripheral microcirculation/peripheral circulation disturbances during acute stress"
],
"main_findings": "Terahertz electromagnetic irradiation at 150.176–150.664 GHz (frequencies corresponding to nitric oxide molecular emission/absorption) corrected disturbances in peripheral circulation typical of an acute stress reaction in rats during acute immobilization stress.",
"effect_direction": "benefit",
"limitations": [
"No sample size reported in abstract",
"Exposure duration and dosimetry (e.g., SAR) not reported in abstract",
"Outcome measurement methods not described in abstract"
],
"evidence_strength": "low",
"confidence": 0.66000000000000003108624468950438313186168670654296875,
"peer_reviewed_likely": "yes",
"keywords": [
"terahertz",
"millimeter wave",
"nitric oxide frequencies",
"150.176-150.664 GHz",
"microcirculation",
"peripheral circulation",
"acute stress",
"immobilization stress",
"rats"
],
"suggested_hubs": [
{
"slug": "mmwave-terahertz",
"weight": 0.90000000000000002220446049250313080847263336181640625,
"reason": "Animal study using terahertz/mmWave exposure (150 GHz range) with physiological outcomes."
}
]
}
AI can be wrong. Always verify against the paper.
AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect.
This content is for informational purposes only and is not medical advice.