Effects of Intermittent and Continuous Magnetic Fields on Trace Element Levels in Guinea Pigs
Abstract
Effects of Intermittent and Continuous Magnetic Fields on Trace Element Levels in Guinea Pigs Erdem O, Akay C, Cevher SC, Canseven AG, Aydın A, Seyhan N. Effects of Intermittent and Continuous Magnetic Fields on Trace Element Levels in Guinea Pigs.Biol Trace Elem Res. 2017 May 22. doi: 10.1007/s12011-017-1053- 8. Abstract Electromagnetic fields (EMFs) can affect living cells due to biochemical changes, followed by changes in levels of trace elements in serum and different organs. This study focuses on the effect of whole body exposure to EMF, presented everywhere in our environment, and on the levels of trace elements in serum, femur, brain, kidney, and liver tissues. The analyses performed on 29 guinea pigs were divided into five groups. Guinea pigs were exposed to a magnetic field of 50 Hz of 1.5 mT. Groups A and B were exposed to the magnetic field for a period of 4 h/day continuously (4 h/day) for 4 and 7 days, respectively. Groups C and D were exposed to the magnetic field for a period of 4 h/day intermittently for 4 and 7 days, respectively. Group E animals were enrolled as control. Copper (Cu), zinc (Zn), calcium (Ca), and magnesium (Mg) levels were determined by atomic absorption spectroscopy in serum, femur, brain, kidney, and liver tissues in all guinea pigs. When compared to the control groups, the changes in the levels of Cu in serum samples, femur, and kidney tissues of the treated groups were statistically significant. The same was also true for the levels of Mg in the brain, kidney, and lung tissues. Our results suggest that in vivo continuous and intermittent exposure to EMF may cause disturbances in homeostasis of bioelements. These effects could be important risk factors for toxic effects of EMF, especially in relation to deterioration of bioelements.
AI evidence extraction
Main findings
Guinea pigs were whole-body exposed to a 50 Hz, 1.5 mT magnetic field for 4 h/day either continuously or intermittently for 4 or 7 days. Compared with controls, statistically significant changes were reported for Cu levels in serum, femur, and kidney in exposed groups, and for Mg levels in brain, kidney, and lung tissues.
Outcomes measured
- Serum copper (Cu) level
- Serum zinc (Zn) level
- Serum calcium (Ca) level
- Serum magnesium (Mg) level
- Femur Cu/Zn/Ca/Mg levels
- Brain Cu/Zn/Ca/Mg levels
- Kidney Cu/Zn/Ca/Mg levels
- Liver Cu/Zn/Ca/Mg levels
Limitations
- Journal name not provided in metadata (though cited in abstract)
- Specific direction/magnitude of trace element changes not reported in the abstract
- Lung tissue is mentioned in results but not listed among the initially described sampled tissues
- No details provided on randomization/blinding or exposure setup beyond frequency/intensity and schedule
Suggested hubs
-
occupational-exposure
(0.2) Study involves ELF (50 Hz) magnetic field exposure, which can be relevant to occupational ELF contexts, though the source is not specified.
View raw extracted JSON
{
"study_type": "animal",
"exposure": {
"band": "ELF",
"source": null,
"frequency_mhz": 0.05000000000000000277555756156289135105907917022705078125,
"sar_wkg": null,
"duration": "4 h/day for 4 or 7 days (continuous or intermittent)"
},
"population": "Guinea pigs",
"sample_size": 29,
"outcomes": [
"Serum copper (Cu) level",
"Serum zinc (Zn) level",
"Serum calcium (Ca) level",
"Serum magnesium (Mg) level",
"Femur Cu/Zn/Ca/Mg levels",
"Brain Cu/Zn/Ca/Mg levels",
"Kidney Cu/Zn/Ca/Mg levels",
"Liver Cu/Zn/Ca/Mg levels"
],
"main_findings": "Guinea pigs were whole-body exposed to a 50 Hz, 1.5 mT magnetic field for 4 h/day either continuously or intermittently for 4 or 7 days. Compared with controls, statistically significant changes were reported for Cu levels in serum, femur, and kidney in exposed groups, and for Mg levels in brain, kidney, and lung tissues.",
"effect_direction": "harm",
"limitations": [
"Journal name not provided in metadata (though cited in abstract)",
"Specific direction/magnitude of trace element changes not reported in the abstract",
"Lung tissue is mentioned in results but not listed among the initially described sampled tissues",
"No details provided on randomization/blinding or exposure setup beyond frequency/intensity and schedule"
],
"evidence_strength": "low",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "unknown",
"keywords": [
"extremely low frequency",
"ELF magnetic field",
"50 Hz",
"1.5 mT",
"guinea pig",
"whole-body exposure",
"intermittent exposure",
"continuous exposure",
"trace elements",
"copper",
"magnesium",
"zinc",
"calcium",
"atomic absorption spectroscopy",
"serum",
"brain",
"kidney",
"liver",
"femur"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.200000000000000011102230246251565404236316680908203125,
"reason": "Study involves ELF (50 Hz) magnetic field exposure, which can be relevant to occupational ELF contexts, though the source is not specified."
}
]
}
AI can be wrong. Always verify against the paper.
Comments
Log in to comment.