Cellular Phone Irradiation of the Head Affects Heart Rate Variability Depending on Inspiration/Expiration Ratio
Abstract
Cellular Phone Irradiation of the Head Affects Heart Rate Variability Depending on Inspiration/Expiration Ratio Béres S, Németh Á, Ajtay Z, Kiss I, Németh B, Hejjel L. Cellular Phone Irradiation of the Head Affects Heart Rate Variability Depending on Inspiration/Expiration Ratio. In Vivo. 2018 Sep-Oct;32(5):1145-1153. doi: 10.21873/invivo.11357. Abstract BACKGROUND: Mobile phones may have harmful health effects and clinical examinations report ambiguous results of exposure concerning neurophysiological and cardiovascular actions. MATERIALS AND METHODS: This study investigated heart rate asymmetry (HRA) and heart rate variability (HRV) parameters with 1:2 and 1:1 metronome-paced inspiration/expiration ratios during short-term 1,800MHz GSM cellular phone exposure in 20 healthy volunteers. RESULTS: Significant HRA changes by Porta and Guzik indices were not found on exposure compared to sham exposure. Time-domain HRV parameters on exposure showed significant differences at 1:1 paced, but not at 1:2 paced breathing compared to sham exposure. A mild post-exposure effect was observed regarding root mean square of successive RR-differences. CONCLUSION: The findings reflect persisting acute effects of GSM handset emission on the autonomic nervous system. Exploring its influences on health status and survival needs further studies. Symmetrical breathing can be used as a sensitizing factor in other HRV/HRA analysis studies. Open access paper: ncbi.nlm.nih.gov
AI evidence extraction
Main findings
Compared with sham exposure, no significant exposure-related changes were found in HRA by Porta and Guzik indices. Time-domain HRV parameters showed significant differences during exposure at 1:1 paced breathing but not at 1:2 paced breathing; a mild post-exposure effect was observed for RMSSD.
Outcomes measured
- heart rate asymmetry (HRA)
- heart rate variability (HRV)
- Porta index
- Guzik index
- time-domain HRV parameters
- root mean square of successive RR-differences (RMSSD)
Suggested hubs
-
mobile-phones-rf
(0.9) Short-term 1,800 MHz GSM cellular phone (handset) exposure compared with sham.
View raw extracted JSON
{
"study_type": "randomized_trial",
"exposure": {
"band": "RF",
"source": "mobile phone",
"frequency_mhz": 1800,
"sar_wkg": null,
"duration": "short-term"
},
"population": "20 healthy volunteers",
"sample_size": 20,
"outcomes": [
"heart rate asymmetry (HRA)",
"heart rate variability (HRV)",
"Porta index",
"Guzik index",
"time-domain HRV parameters",
"root mean square of successive RR-differences (RMSSD)"
],
"main_findings": "Compared with sham exposure, no significant exposure-related changes were found in HRA by Porta and Guzik indices. Time-domain HRV parameters showed significant differences during exposure at 1:1 paced breathing but not at 1:2 paced breathing; a mild post-exposure effect was observed for RMSSD.",
"effect_direction": "mixed",
"limitations": [],
"evidence_strength": "low",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"GSM",
"1800 MHz",
"cellular phone",
"handset emission",
"sham exposure",
"heart rate variability",
"heart rate asymmetry",
"autonomic nervous system",
"paced breathing",
"inspiration/expiration ratio"
],
"suggested_hubs": [
{
"slug": "mobile-phones-rf",
"weight": 0.90000000000000002220446049250313080847263336181640625,
"reason": "Short-term 1,800 MHz GSM cellular phone (handset) exposure compared with sham."
}
]
}
AI can be wrong. Always verify against the paper.