Specific absorption rate variation in a brain phantom due to exposure by a 3G mobile phone: problems in dosimetry.
Research
RF Safe Research Library
Jan 1, 2013
This paper describes a SAR measurement system for a 3G mobile phone (1718.5 MHz) using brain phantom material in a Perspex box sized to a small rat volume, with induced fields measured at multiple locations. SAR was computed from induced-field measurements and also estimated experimentally via temperature rise, with…
Polymer-disordered liquid crystals: susceptibility to an electric field.
Research
RF Safe Research Library
Jan 1, 2013
This study models nematic liquid crystals embedded in random polymer networks, where disorder disrupts long-range order and produces a glassy state. It uses simulations and an Imry-Ma-like analytic approach to visualize domains, predict domain size, and calculate the response to an applied electric field. The authors…
Three-dimensional dynamics of a particle with a finite energy of magnetic anisotropy in a rotating magnetic field.
Research
RF Safe Research Library
Jan 1, 2013
This paper presents a theoretical model of a single ferromagnetic particle with finite coupling between its magnetic moment and particle body in a rotating magnetic field. It describes synchronous and asynchronous motion regimes, including planar motion at low frequencies and a precession regime at high frequencies,…
Comparison of 2 methods of non-invasive treatment between transcutaneous electrical stimulation and pulsed electromagnetic field stimulation as replacement of invasive manual acupuncture.
Research
RF Safe Research Library
Jan 1, 2012
This study compared two non-invasive acupoint stimulation methods—TEAS and PEMF—as alternatives to manual acupuncture for recovery from exercise-induced muscle fatigue. Using 2 Hz stimulation (PEMF magnetic flux 30.92 mT), the authors report faster recovery of EMG median frequency and improved peak torque recovery in…
[Study on atmospheric VOCs in Gongga Mountain base station].
Research
RF Safe Research Library
Jan 1, 2012
This study measured atmospheric VOCs at the Gongga Mountain base station using weekly samples collected in 2007 and analyzed by preconcentration plus GC-MS. It reports mean concentrations of TVOCs and NMHCs, describes VOC composition, and uses PCA-based receptor modeling to attribute sources. The authors report…
Comparison between different thickness umbrella-shaped expandable radiofrequency electrodes (SuperSlim and CoAccess): Experimental and clinical study.
Research
RF Safe Research Library
Jan 1, 2011
This experimental and clinical study compared two umbrella-shaped expandable radiofrequency ablation electrodes (SuperSlim vs CoAccess) across different ablation algorithms. In ex vivo bovine liver, CoAccess generally produced larger ablation areas and required longer ablation times than SuperSlim, with no…
Template-free synthesis and self-assembly of aligned nickel nanochains under magnetic fields.
Research
RF Safe Research Library
Jan 1, 2011
This engineering/materials study describes a template-free solution-phase method to synthesize well-aligned nickel nanochains under applied magnetic fields. The authors report that nanochain size and morphology can be tuned by reaction temperature and magnetic field conditions, and explain alignment via magnetic…
Hyperthermic effects of dissipative structures of magnetic nanoparticles in large alternating magnetic fields.
Research
RF Safe Research Library
Jan 1, 2011
This paper addresses heat dissipation mechanisms of magnetic nanoparticles used in targeted hyperthermia under large alternating magnetic fields. Using numerical comparisons, it reports additional features in relaxation loss for rotatable superparamagnetic nanoparticles and field-induced formation of oriented…
Isolated Atrial Lead Conduction Delay following Right Atrial Radiofrequency Maze Procedure.
Research
RF Safe Research Library
Jan 1, 2011
This case report describes a 60-year-old man with a dual-chamber implantable cardioverter defibrillator who underwent septal myectomy and a right atrial radiofrequency maze procedure. Following surgery, a persistent delay in atrial sensing was observed. The authors attribute this most likely to iatrogenic right…
A radiofrequency coil to facilitate B₁⁺ shimming and parallel imaging acceleration in three dimensions at 7 T.
Research
RF Safe Research Library
Jan 1, 2011
This paper reports the development of a 15-channel transmit-receive RF coil for 7 T human brain MRI, using a hybrid decoupling approach to support element placement along three axes. The design is presented as enabling B1+ shimming and parallel imaging acceleration in three dimensions, with reported isolation and…
Selenium supplementation ameliorates static magnetic field-induced disorders in antioxidant status in rat tissues.
Research
RF Safe Research Library
Jan 1, 2011
This rat study examined whether selenium supplementation modifies antioxidant-related changes associated with sub-acute static magnetic field exposure. The authors report that SMF exposure altered tissue selenium levels and antioxidant enzyme activities in a tissue-specific manner, including decreased selenium and…
Influence of pulsed electric field treatments on the volatile compounds of milk in comparison with pasteurized processing.
Research
RF Safe Research Library
Jan 1, 2011
The paper evaluates how pulsed electric field (PEF) processing affects milk volatile compounds compared with HTST pasteurization (75 °C, 15 s). GC-MS detected 37 volatiles and reported some compositional differences between PEF and pasteurized milk, including increased aldehydes and lower methyl ketones with PEF.…
Spin current pumped by a rotating magnetic field in zigzag graphene nanoribbons.
Research
RF Safe Research Library
Jan 1, 2010
This theoretical study models electron spin resonance and spin/charge pumping in zigzag graphene nanoribbons driven by a transverse rotating magnetic field without applied bias. It reports that pumped spin current density increases with ribbon size and rotating-field intensity, and that even-chain ribbons can also…
The effect of magnetic field and disorders on the electronic transport in graphene nanoribbons.
Research
RF Safe Research Library
Jan 1, 2010
This paper presents a mesoscopic transport modeling framework (NEGF plus a real-space π-orbital model) to study how a uniform perpendicular magnetic field affects electronic transport in armchair graphene nanoribbons. The authors report width-dependent equilibrium current profiles and edge-localized transport under…
Thermodynamic behavior of the XXZ Heisenberg s = 1/2 chain around the factorizing magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This paper theoretically investigates zero- and finite-temperature behavior of an anisotropic antiferromagnetic Heisenberg XXZ spin-1/2 chain under a transverse magnetic field, focusing between the factorizing and critical fields. It reports an entanglement phase transition at the factorizing field where entanglement…
An extension of the Czjzek model for the distributions of electric field gradients in disordered solids and an application to NMR spectra of 71Ga in chalcogenide glasses.
Research
RF Safe Research Library
Jan 1, 2010
This paper discusses the Czjzek model for distributions of electric field gradient (EFG) tensors in disordered solids and highlights its underlying assumptions and characteristics. It then introduces an extended model that combines a defined local EFG environment with an adjustable Gaussian (Czjzek) noise term to…
Ultrasonic propagation velocity in magnetic and magnetorheological fluids due to an external magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
This engineering-focused study measured ultrasonic propagation velocity in hydrocarbon-based magnetic and magnetorheological fluids under an external magnetic field. The authors report that clustering structures formed in the fluids influence ultrasonic propagation velocity, with observed hysteresis and anisotropy.…
Disordered electrical potential observed on the surface of SiO2 by electric field microscopy.
Research
RF Safe Research Library
Jan 1, 2010
This study characterizes the electrical potential on the surface of ~300 nm SiO2 grown on single-crystalline Si under ambient conditions using electric field microscopy. It reports an inhomogeneous surface potential with fluctuations up to ~0.4 V over ~1 µm regions. The authors propose these fluctuations could affect…
Localizing Broca's area for transcranial magnetic stimulation: Comparison of surface distance measurements and stereotaxic positioning.
Research
RF Safe Research Library
Jan 1, 2009
This methods study evaluated an MRI-based surface distance measurements (SDM) approach for localizing Broca's area for TMS coil placement without external tracking devices. Coil positioning using SDM was compared with an advanced frameless stereotaxic navigation system. The reported mean difference between methods…
A comparison of conventional and radio frequency defrosting of lean beef meats: Effects on water binding characteristics.
Research
RF Safe Research Library
Jan 1, 2009
This study compared slow conventional air defrosting with fast radio frequency (RF) defrosting/tempering in lean beef (whole, minced, and comminuted) using drip loss, NMR relaxometry, and dielectric spectroscopy. RF thawing was associated with lower drip loss and lower micronutrient loss in drip than air thawing,…
Electric field switching of the magnetic anisotropy of a ferromagnetic layer exchange coupled to the multiferroic compound BiFeO3.
Research
RF Safe Research Library
Jan 1, 2009
This paper reports electric-field control of magnetic anisotropy in a Permalloy layer exchange-coupled to a multiferroic BiFeO3 single crystal. The anisotropy is described as arising from magnetic coupling to canted spins in BiFeO3’s cycloidal antiferromagnetic structure. An electric field-induced polarization change…
Dominant mobility modulation by the electric field effect at the LaAlO3/SrTiO3 interface.
Research
RF Safe Research Library
Jan 1, 2009
This Physical Review Letters paper reports magnetotransport measurements on a gated LaAlO3/SrTiO3 interface to assess the main effect of an applied gate electric field. The authors find that mobility changes dominate over sheet carrier density changes (mobility variation reported as nearly fivefold larger). They also…
Quasiparticles of spatially anisotropic triangular antiferromagnets in a magnetic field.
Research
RF Safe Research Library
Jan 1, 2009
This theoretical/physics study investigates spectral properties of a spin-1/2 Heisenberg antiferromagnet on an anisotropic triangular lattice in a magnetic field. It reports that interchain interactions in a magnetic field generate dominant modes that behave as quasiparticles, featuring anomalous incommensurate…
Sham Transcranial Magnetic Stimulation Using Electrical Stimulation of the Scalp.
Research
RF Safe Research Library
Jan 1, 2009
This study describes development and validation of a sham rTMS approach that combines a matched sham coil (for look/sound) with scalp electrical stimulation (for sensation). In back-to-back comparisons, TMS-naïve participants reportedly could not tell active from sham, whereas experienced participants could. The…
Head-to-head comparison of coronary plaque evaluation between multislice computed tomography and intravascular ultrasound radiofrequency data analysis.
Research
RF Safe Research Library
Jan 1, 2008
This study compared coronary plaque assessment by 64-slice multislice computed tomography (MSCT) with virtual histology intravascular ultrasound (VH IVUS) in 50 patients. The Agatston score on MSCT correlated moderately with calcium volume measured by VH IVUS, and MSCT plaque categories broadly reflected differences…