Archive

894 posts

Showing results for: rat

Aggregation of magnetic holes in a rotating magnetic field.

Research RF Safe Research Library Jan 1, 2008

This laboratory study experimentally examined aggregation of nonmagnetic particles in a magnetic fluid layer under a rotating magnetic field. Particles formed two-dimensional clusters that repeatedly aggregated into larger clusters, producing a broad distribution of cluster sizes. The dynamics were described as…

[Radiofrequency aviation treatment for lingual root obstructive sleep apnea-hypopnea syndrome].

Research RF Safe Research Library Jan 1, 2008

This clinical study reports outcomes for 34 patients with mild and median OSAHS treated with a combination of functional endoscopic sinus surgery, UPPP, and radiofrequency ablation (RFA). Over 1 year, polysomnography showed a reduction in AHI and an effective rate of 85.29%. Because RFA was used as an adjunct to…

[Determination of electric field distribution in dielectric barrier surface glow discharge by spectroscopic method].

Research RF Safe Research Library Jan 1, 2008

This engineering study reports spectroscopic determination of net electric field distribution in a dielectric barrier surface glow discharge in low-pressure air. Optical emission spectroscopy was used to infer electric field distribution from the intensity ratio of nitrogen spectral lines at 391.4 nm and 337.1 nm.…

Effect of temperature (-5 to 130 degrees C) and fiber direction on the dielectric properties of beef Semitendinosus at radio frequency and microwave frequencies.

Research RF Safe Research Library Jan 1, 2008

This study measured dielectric properties of beef Semitendinosus across 27, 915, and 1800 MHz and temperatures from -5 to 130 °C using an open-ended coaxial probe. The results indicate that frequency, temperature, and muscle fiber orientation influence dielectric constant, dielectric loss, and calculated penetration…

Adverse effects of excessive mobile phone use.

Research RF Safe Research Library Jan 1, 2008

This cross-sectional questionnaire study surveyed 286 medical students about mobile phone use and health complaints. The abstract reports multiple self-reported symptoms (including impaired concentration, memory disturbances, sleeplessness, fatigue, and headache) and notes that 44.4% of respondents attributed their…

Influence of mashed potato dielectric properties and circulating water electric conductivity on radio frequency heating at 27 MHz.

Research RF Safe Research Library Jan 1, 2008

This engineering study used experiments, computer simulations, and simplified analytical calculations to examine how mashed potato dielectric properties and circulating water electrical conductivity affect RF heating at 27 MHz. The authors report that higher circulating water conductivity and higher salt content in…

Electronic response properties of carbon nanotubes in magnetic fields.

Research RF Safe Research Library Jan 1, 2008

This computational study investigates magnetic linear response properties of achiral and chiral carbon nanotubes using first-principles electronic structure methods. It computes magnetic shielding inside and outside nanotubes due to electronic currents induced by external magnetic fields applied parallel or…

Plasma-assembled carbon nanotubes: electric field-related effects.

Research RF Safe Research Library Jan 1, 2008

This engineering-focused paper compares carbon nanotube growth in dense low-temperature plasma versus on a substrate surface using hybrid/Monte-Carlo simulations. It reports that plasma parameters strongly influence ion fluxes and nanotube growth kinetics, with large differences in growth rates and fluxes between…

Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart.

Research RF Safe Research Library Jan 1, 2008

This engineering study addresses interference between induction-heating cookers and an externally coupled transcutaneous energy transmission system for a totally implantable artificial heart. The authors report that magnetic flux from an IH cooker can couple into the TET transformer and affect system performance. A…

In vivo quantification of contrast agent concentration using the induced magnetic field for time-resolved arterial input function measurement with MRI.

Research RF Safe Research Library Jan 1, 2008

This Medical Physics article presents a phase-based MRI method to quantify paramagnetic contrast agent concentration by inverting susceptibility-induced magnetic field shifts, aiming to improve arterial input function (AIF) measurement in DCE-MRI. After in vitro validation, the approach was applied in vivo in 14…

[Microstrip antenna design and system research of radio frequency identification temperature sensor].

Research RF Safe Research Library Jan 1, 2008

This engineering paper introduces an RFID sensor network concept integrating RFID with wireless sensor networks and emphasizes the role of antennas. It discusses coil, dipole, and microstrip antennas and reports designing a microstrip antenna for a wireless temperature monitoring and control system. Measurements are…

Minimal-SAR RF pulse optimization for parallel transmission in MRI.

Research RF Safe Research Library Jan 1, 2008

This engineering study presents an optimization framework to design RF pulses for parallel transmission MRI with the goal of minimizing SAR. Using computer simulations of a 4-channel system, the authors report significant SAR reduction while maintaining excitation pattern quality and without increasing pulse…

Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS).

Research RF Safe Research Library Jan 1, 2008

This engineering-focused conference paper proposes figures of merit to evaluate deep-brain transcranial magnetic stimulation (dTMS) coil designs, focusing on depth penetration, scalp stimulation, focality, and energy. It analyzes circular crown and C-core coils and reports reduced electric-field attenuation with…

Chemotherapy side-effect management using mobile phones.

Research RF Safe Research Library Jan 1, 2008

This conference paper describes a mobile-phone telemedicine system for managing chemotherapy side-effects at home using symptom diaries and automated alerts to nurses. Six patients used the system for two cycles of oral chemotherapy. The abstract reports two instances where moderate symptoms deteriorated to more…

Electromagnetic interference to infusion pumps. Update2008 from GSM mobile phones.

Research RF Safe Research Library Jan 1, 2008

This engineering study updates a prior (2005) survey on electromagnetic interference (EMI) affecting infusion pumps and extends testing to DECT phones and WiFi terminals. It reports a reduced failure rate for GSM phone exposure compared with 2005 (58% to 30%). The authors report that WiFi and DECT did not pose a real…

Single access point localisation for wearable wireless sensors.

Research RF Safe Research Library Jan 1, 2008

This engineering conference paper describes a single access point method for localizing a subject using RF signals from wearable wireless sensors. The approach combines RSSI and LQI measurements from one basestation and applies filtering. The abstract reports that accuracy can approach that of multi-basestation…

Radiofrequency dosimetry in subjects implanted with metallic straight wires: a numerical study.

Research RF Safe Research Library Jan 1, 2008

This numerical FDTD study modeled RF exposure at 900 and 1800 MHz in tissue containing thin metallic straight wire implants. The model indicates that the wire can substantially increase local SAR, creating high SAR gradients. Despite this, the authors report that exposures below current safe levels resulted in…

Combined effect of temperature and pulsed electric fields on apple juice peroxidase and polyphenoloxidase inactivation.

Research RF Safe Research Library Jan 1, 2008

This laboratory study evaluated pulsed electric fields (PEF) combined with preheating to inactivate peroxidase (POD) and polyphenoloxidase (PPO) in freshly prepared apple juice. The highest reported inactivation occurred with preheating to 50°C and PEF at 40 kV/cm for 100 μs, exceeding the reductions seen with…

Position-independent chemical quantitation with passive 13.56-MHz radio frequency identification (RFID) sensors.

Research RF Safe Research Library Jan 1, 2008

This engineering study evaluates whether passive 13.56-MHz RFID-based chemical sensors can quantify analytes reliably despite repositioning errors between the sensor and pickup coil. Using simultaneous measurement of multiple complex-impedance parameters and multivariate statistical analysis, the authors report…

In-line application of electric field in capillary separation systems: Joule heating, pH and conductivity.

Research RF Safe Research Library Jan 1, 2008

This engineering study investigated factors affecting current when an electric field is applied in-line in a capillary separation system. Temperature measurements and a replicated cooling setup were used to estimate Joule heating effects, which were reported to be relatively small. In contrast, significant pH shifts…

A benzene-core trinuclear GdIII complex: towards the optimization of relaxivity for MRI contrast agent applications at high magnetic field.

Research RF Safe Research Library Jan 1, 2008

This chemistry/engineering study reports the synthesis and NMR/MRI-relevant characterization of a trinuclear Gd(III) chelate intended for high-field MRI contrast applications. Using 17O NMR and proton relaxivity across multiple fields and temperatures, the authors infer bishydration, quantify water exchange and…

Microscopic observation of living cells during their exposure to modulated electromagnetic fields.

Research RF Safe Research Library Jan 1, 2008

This paper describes an exposure and microscopy system designed to continuously observe living cells during exposure to modulated RF-EMF similar to mobile phone signals. Using protocols where the same cells serve as controls before and after exposure, the system was validated with endocytosis measurements. Under 900…

Ultrastructural alterations and occurrence of apoptosis in developing follicles exposed to low frequency electromagnetic field in rat ovary.

Research RF Safe Research Library Jan 1, 2007

This animal study examined rat ovaries after chronic exposure to a 3 mT low-frequency electromagnetic field for 4 hours per day over 4 months. Using TEM and TUNEL, the authors report ultrastructural alterations in oocytes and more frequent apoptosis-associated changes in granulosa and corona radiata cells versus…

Effects of electromagnetic field produced by mobile phones on the oxidant and antioxidant status of rats.

Research RF Safe Research Library Jan 1, 2007

This rat study examined whether EMR from GSM mobile phones affects oxidant/antioxidant status. Compared with controls, exposed rats had lower plasma antioxidant vitamins (C, E, A), reduced glutathione, and lower CAT and SOD activities. The acute exposure condition was reported to produce larger decreases than the…

Exposure to an additional alternating magnetic field affects comb building by worker hornets.

Research RF Safe Research Library Jan 1, 2007

This animal study reports that exposing worker oriental hornets in an artificial breeding box to an additional 50 Hz magnetic field (50–70 mGauss) altered comb construction compared with controls under only the terrestrial magnetic field. The abstract describes fewer cells and eggs, more deformed cell geometry, and…

← Prev Page 35 / 36 Next →