Two-dimensional electron states bound to an off-plane donor in a magnetic field.
Research
RF Safe Research Library
Jan 1, 2010
A theoretical analysis is presented of electron states in a two-dimensional plane bound to an off-plane donor impurity under a magnetic field. The authors calculate energy levels (ground and first three excited states) variationally and report binding energies and mean orbital radii as functions of donor position and…
Nanocrystalline hydroxyapatite bioceramic using microwave radiation: Synthesis and characterization.
Research
RF Safe Research Library
Jan 1, 2010
This engineering/materials study synthesized nanocrystalline hydroxyapatite bioceramic powder using microwave radiation and then characterized the resulting material. The authors report highly crystalline HAp nanopowder with nanoscale size, mixed morphology, and elemental composition consistent with the HAp phase.…
Electromagnetic fields and DNA damage
Research
RF Safe Research Library
Jan 1, 2009
This review discusses the comet assay and summarizes research on non-ionizing EMF exposure and DNA/chromosomal damage. It describes both positive and negative findings across studies, noting no consistent overall pattern for radiofrequency radiation (RFR). The authors nonetheless conclude that under certain exposure…
Localizing Broca's area for transcranial magnetic stimulation: Comparison of surface distance measurements and stereotaxic positioning.
Research
RF Safe Research Library
Jan 1, 2009
This methods study evaluated an MRI-based surface distance measurements (SDM) approach for localizing Broca's area for TMS coil placement without external tracking devices. Coil positioning using SDM was compared with an advanced frameless stereotaxic navigation system. The reported mean difference between methods…
Plasmonic array nanoantennas on layered substrates: modeling and radiation characteristics.
Research
RF Safe Research Library
Jan 1, 2009
This theoretical/engineering study models arrays of plasmonic core-shell nano-radiators positioned over layered substrates using a Green's function dipole approach. The model is validated with full-wave FDTD simulations. The authors report that nanoparticle arraying and multilayer substrate design can be used to…
Dominant mobility modulation by the electric field effect at the LaAlO3/SrTiO3 interface.
Research
RF Safe Research Library
Jan 1, 2009
This Physical Review Letters paper reports magnetotransport measurements on a gated LaAlO3/SrTiO3 interface to assess the main effect of an applied gate electric field. The authors find that mobility changes dominate over sheet carrier density changes (mobility variation reported as nearly fivefold larger). They also…
[Female genital toxicities of high-frequency electromagnetic field on rats].
Research
RF Safe Research Library
Jan 1, 2009
This rat study examined sub-chronic exposure to a 30 MHz electromagnetic field at 0–1600 V/m for 8 hours/day, 5 days/week, over 56 days. The authors report no change in ovarian wet weight, but dose-related changes in estrous cycle timing, reproductive hormones (higher LH and lower E2 at higher exposures), and ovarian…
[Effect of microwave radiation on primary cultured Sertoli cells].
Research
RF Safe Research Library
Jan 1, 2009
This in vitro study exposed primary cultured Sertoli cells to microwave radiation at 0, 30, or 100 mW/cm^2 for 5 minutes and assessed outcomes 6 hours later. The authors report no differences in apoptosis/death or intracellular Ca2+ at 30 mW/cm^2, though cell-cycle distribution shifted. At 100 mW/cm^2, intracellular…
Static magnetic field therapy: a critical review of treatment parameters.
Research
RF Safe Research Library
Jan 1, 2009
This critical review summarizes human research on static magnetic field (SMF) therapy delivered by permanent magnets attached to the skin and evaluates how well studies report SMF dosage and treatment parameters. Across 56 included studies, many did not report essential SMF characteristics (e.g., magnet dimensions,…
Head-to-head comparison of coronary plaque evaluation between multislice computed tomography and intravascular ultrasound radiofrequency data analysis.
Research
RF Safe Research Library
Jan 1, 2008
This study compared coronary plaque assessment by 64-slice multislice computed tomography (MSCT) with virtual histology intravascular ultrasound (VH IVUS) in 50 patients. The Agatston score on MSCT correlated moderately with calcium volume measured by VH IVUS, and MSCT plaque categories broadly reflected differences…
Velocity modulation of microtubules in electric fields.
Research
RF Safe Research Library
Jan 1, 2008
This in vitro study reports that electric fields can control the velocity of microtubules gliding over a kinesin-coated surface. Assisting fields increased speed up to fivefold, while opposing fields slowed motion to zero, and sideways fields induced significant motion. The authors present a grab-and-release model to…
Use of terahertz electromagnetic radiation for correction of blood rheology parameters in patients with unstable angina under conditions of treatment with isoket, an NO donor.
Research
RF Safe Research Library
Jan 1, 2008
This in vitro study examined terahertz electromagnetic radiation at NO-related spectral frequencies and its effects on blood rheology in patients with unstable angina treated with the NO donor isoket. The abstract reports that irradiated isoket had a better normalizing effect on blood viscosity and erythrocyte…
Intestinal MMC-related electric fields and pancreatic juice control the adhesion of Gram-positive and Gram-negative bacteria to the gut epithelium--in vitro study.
Research
RF Safe Research Library
Jan 1, 2008
This in vitro study tested whether a weak electric field reconstructed from duodenal spiking potentials during an MMC cycle affects bacterial adhesion to Caco-2 intestinal epithelial cells. The MMC-related electric field increased adhesion of Lactobacillus and Lactococcus strains, while two pathogenic strains…
Greyscale intravascular ultrasound and IVUS-radiofrequency tissue characterisation to improve understanding of the mechanisms of coronary stent thrombosis in drug-eluting stents.
Research
RF Safe Research Library
Jan 1, 2008
This review describes proposed mechanical causes of drug-eluting stent thrombosis and notes that many are identifiable by greyscale intravascular ultrasound (IVUS). It highlights that evidence linking specific IVUS findings to stent thrombosis remains uncertain because relatively few stent thrombosis cases have been…
Radiofrequency dosimetry in subjects implanted with metallic straight wires: a numerical study.
Research
RF Safe Research Library
Jan 1, 2008
This numerical FDTD study modeled RF exposure at 900 and 1800 MHz in tissue containing thin metallic straight wire implants. The model indicates that the wire can substantially increase local SAR, creating high SAR gradients. Despite this, the authors report that exposures below current safe levels resulted in…
Position-independent chemical quantitation with passive 13.56-MHz radio frequency identification (RFID) sensors.
Research
RF Safe Research Library
Jan 1, 2008
This engineering study evaluates whether passive 13.56-MHz RFID-based chemical sensors can quantify analytes reliably despite repositioning errors between the sensor and pickup coil. Using simultaneous measurement of multiple complex-impedance parameters and multivariate statistical analysis, the authors report…
Microscopic observation of living cells during their exposure to modulated electromagnetic fields.
Research
RF Safe Research Library
Jan 1, 2008
This paper describes an exposure and microscopy system designed to continuously observe living cells during exposure to modulated RF-EMF similar to mobile phone signals. Using protocols where the same cells serve as controls before and after exposure, the system was validated with endocytosis measurements. Under 900…
Ultrastructural alterations and occurrence of apoptosis in developing follicles exposed to low frequency electromagnetic field in rat ovary.
Research
RF Safe Research Library
Jan 1, 2007
This animal study examined rat ovaries after chronic exposure to a 3 mT low-frequency electromagnetic field for 4 hours per day over 4 months. Using TEM and TUNEL, the authors report ultrastructural alterations in oocytes and more frequent apoptosis-associated changes in granulosa and corona radiata cells versus…
Exposure to an additional alternating magnetic field affects comb building by worker hornets.
Research
RF Safe Research Library
Jan 1, 2007
This animal study reports that exposing worker oriental hornets in an artificial breeding box to an additional 50 Hz magnetic field (50–70 mGauss) altered comb construction compared with controls under only the terrestrial magnetic field. The abstract describes fewer cells and eggs, more deformed cell geometry, and…
900 MHz radiofrequency-induced histopathologic changes and oxidative stress in rat endometrium: protection by vitamins E and C.
Research
RF Safe Research Library
Jan 1, 2007
This rat study examined 900 MHz radiofrequency exposure (30 min/day for 30 days) and reported biochemical and histopathologic changes in endometrial tissue consistent with oxidative stress and tissue injury. The abstract reports increased NO and MDA and decreased antioxidant enzyme activities (SOD, CAT, GSH-Px) in…
[Operational aspects of risk perception in the electromagnetic fields exposition].
Research
RF Safe Research Library
Jan 1, 2007
This study reports on symptomatology and risk perception among 45 people living near power-lines in the Benevento area. Although measured electric and magnetic fields were described as being within the normal range, participants reported symptoms mainly in subjective and behavioural domains. The authors argue that…
[ELF-MF occupational exposure: repeated measures on workers].
Research
RF Safe Research Library
Jan 1, 2007
This occupational exposure assessment used personal dosimeters to estimate ELF magnetic field exposure in 543 workers across 9 occupational settings in Emilia-Romagna. Median time-weighted average exposure was 0.14 microT, with tile production showing the highest setting-level TWA. Repeat measurements after 6–9…
Dependence of RF heating on SAR and implant position in a 1.5T MR system.
Research
RF Safe Research Library
Jan 1, 2007
This phantom study measured RF-induced heating of a stainless steel humerus implant during 1.5T MR imaging while varying SAR, implant angle to B0, and implant position in the RF coil. Temperature rise at implant tips increased linearly with SAR, with larger rises when the implant was parallel to B0. Heating decreased…
A mobile clinical e-portfolio for nursing and medical students, using wireless personal digital assistants (PDAs).
Research
RF Safe Research Library
Jan 1, 2006
This paper outlines the development and evaluation of a wireless PDA-based clinical e-portfolio intended to support reflective clinical learning. The tool synchronized wirelessly via cellular signal or Wi-Fi to a web-based portfolio. An evaluation with nurse practitioner and medical students reported positive…