Share
𝕏 Facebook LinkedIn

Overwhelming Thermomechanical Motion with Microwave Radiation Pressure Shot Noise.

PAPER pubmed Physical review letters 2016 Engineering / measurement Effect: unclear Evidence: Insufficient

Abstract

We measure the fundamental noise processes associated with a continuous linear position measurement of a micromechanical membrane incorporated in a microwave cavity optomechanical circuit. We observe the trade-off between the two fundamental sources of noise that enforce the standard quantum limit: the measurement imprecision and radiation pressure backaction from photon shot noise. We demonstrate that the quantum backaction of the measurement can overwhelm the intrinsic thermal motion by 24 dB, entering a new regime for cavity optomechanical systems.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
unclear
Population
—
Sample size
—
Exposure
microwave microwave cavity optomechanical circuit
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

In a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can overwhelm intrinsic thermal motion by 24 dB.

Outcomes measured

  • measurement imprecision noise
  • radiation pressure backaction (photon shot noise)
  • thermomechanical (intrinsic thermal) motion
  • standard quantum limit trade-off
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": "microwave",
        "source": "microwave cavity optomechanical circuit",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "measurement imprecision noise",
        "radiation pressure backaction (photon shot noise)",
        "thermomechanical (intrinsic thermal) motion",
        "standard quantum limit trade-off"
    ],
    "main_findings": "In a microwave cavity optomechanical circuit measuring a micromechanical membrane position, the authors observed the trade-off between measurement imprecision and radiation-pressure backaction from photon shot noise. They report that quantum backaction can overwhelm intrinsic thermal motion by 24 dB.",
    "effect_direction": "unclear",
    "limitations": [],
    "evidence_strength": "insufficient",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "microwave",
        "cavity optomechanics",
        "micromechanical membrane",
        "radiation pressure",
        "photon shot noise",
        "quantum backaction",
        "standard quantum limit",
        "thermomechanical motion",
        "position measurement",
        "noise processes"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.