Comparison of electromagnetic exposure for passengers at different positions on the subway platform

PAPER manual 2022 Exposure assessment Effect: no_effect Evidence: Low

Abstract

Comparison of electromagnetic exposure for passengers at different positions on the subway platform Li J, Lu M. Comparison of electromagnetic exposure for passengers at different positions on the subway platform. EMIE 2022; The 2nd International Conference on Electronic Materials and Information Engineering, Hangzhou, China, 2022, pp. 1-6. Abstract To evaluate the safety of electromagnetic exposure for passengers at different positions on the subway platform, the High Frequency Structure Simulator software is used to establish the exposure source, i.e., the leakage coaxial cable model and the adult and child passenger models. Three waiting positions (A, B and C) with an interval of 1.5 m are selected on the subway platform. The distribution of the specific absorption rate of the adult and child passengers at different waiting positions was calculated at 900 MHz. Results show that among the three locations, the maximum SAR values in the adult and child bodies appear at position A nearest to the exposure source, which are 1.5859×10(exp -7) and 1.0854×10(exp -7) W/kg, respectively. According to the comparison of the SAR distribution between the adult and the child at positions A and C, the SAR values in the child’s brain tissue are 4.98 and 2.80 times higher than those of the adult, respectively. The simulation results are well below the International Commission on Non-Ionizing Radiation Protection limits for the general public, indicating that the adult and child passengers do not suffer health risks under the electromagnetic exposure emitted by the leaky coaxial cable on the subway platform. ieeexplore.ieee.org

AI evidence extraction

At a glance
Study type
Exposure assessment
Effect direction
no_effect
Population
Adult and child passenger models (simulation)
Sample size
—
Exposure
RF leaky coaxial cable (subway platform) · 900 MHz
Evidence strength
Low
Confidence: 78% · Peer-reviewed: unknown

Main findings

Using HFSS simulations at 900 MHz for three platform waiting positions (A, B, C), the maximum SAR for both adult and child models occurred at position A (nearest the source): 1.5859×10(exp -7) W/kg (adult) and 1.0854×10(exp -7) W/kg (child). Child brain SAR was higher than adult brain SAR by factors of 4.98 (position A) and 2.80 (position C). Reported SAR values were stated to be well below ICNIRP general public limits.

Outcomes measured

  • Specific absorption rate (SAR) distribution in adult and child bodies
  • Maximum SAR at different waiting positions on platform
  • Child vs adult SAR in brain tissue

Limitations

  • Simulation study (HFSS) rather than measurements in real passengers
  • Exposure source modeled as leakage coaxial cable; other subway RF sources not described
  • Only one frequency reported (900 MHz)
  • Limited to three waiting positions with 1.5 m spacing
  • Health outcomes not measured; conclusions based on comparison to ICNIRP limits

Suggested hubs

  • who-icnirp (0.6)
    Abstract explicitly compares simulated SAR to ICNIRP general public limits.
  • occupational-exposure (0.2)
    Exposure context is a subway platform environment; primarily public/passenger exposure rather than occupational, but related setting.
View raw extracted JSON
{
    "study_type": "exposure_assessment",
    "exposure": {
        "band": "RF",
        "source": "leaky coaxial cable (subway platform)",
        "frequency_mhz": 900,
        "sar_wkg": null,
        "duration": null
    },
    "population": "Adult and child passenger models (simulation)",
    "sample_size": null,
    "outcomes": [
        "Specific absorption rate (SAR) distribution in adult and child bodies",
        "Maximum SAR at different waiting positions on platform",
        "Child vs adult SAR in brain tissue"
    ],
    "main_findings": "Using HFSS simulations at 900 MHz for three platform waiting positions (A, B, C), the maximum SAR for both adult and child models occurred at position A (nearest the source): 1.5859×10(exp -7) W/kg (adult) and 1.0854×10(exp -7) W/kg (child). Child brain SAR was higher than adult brain SAR by factors of 4.98 (position A) and 2.80 (position C). Reported SAR values were stated to be well below ICNIRP general public limits.",
    "effect_direction": "no_effect",
    "limitations": [
        "Simulation study (HFSS) rather than measurements in real passengers",
        "Exposure source modeled as leakage coaxial cable; other subway RF sources not described",
        "Only one frequency reported (900 MHz)",
        "Limited to three waiting positions with 1.5 m spacing",
        "Health outcomes not measured; conclusions based on comparison to ICNIRP limits"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "unknown",
    "keywords": [
        "subway platform",
        "leaky coaxial cable",
        "RF exposure",
        "900 MHz",
        "SAR",
        "HFSS",
        "adult model",
        "child model",
        "ICNIRP"
    ],
    "suggested_hubs": [
        {
            "slug": "who-icnirp",
            "weight": 0.59999999999999997779553950749686919152736663818359375,
            "reason": "Abstract explicitly compares simulated SAR to ICNIRP general public limits."
        },
        {
            "slug": "occupational-exposure",
            "weight": 0.200000000000000011102230246251565404236316680908203125,
            "reason": "Exposure context is a subway platform environment; primarily public/passenger exposure rather than occupational, but related setting."
        }
    ]
}

AI can be wrong. Always verify against the paper.