Lack of an EMF-induced genotoxic effect in the Ames assay.

PAPER pubmed Life sciences 1996 In vitro study Effect: no_effect Evidence: Low

Abstract

A few epidemiological studies have linked exposure to electromagnetic fields (EMF) and the incidence of cancer. Since many carcinogens are mutagens in the Ames assay, the purpose of this study was to determine if exposure of four tester strains of Salmonella typhimurium (TA97a, TA98, TA100, and TA102) to EMF would increase their rate of mutation. Parallel plate electrodes and Helmholtz coils were used to create uniform field properties (300 V/in., 0.3 mT). Separate and combined alternating electric and magnetic fields effects were studied at a combined field frequency of 60, 600, and 6000 Hz at room temperature. These fields did not elevate the temperature of the culture plates above room temperature, Petri dishes containing each tester strain in top agar were exposed to an electric field (E), magnetic field (M), combined electric and magnetic field (EM), or no additional field above ambient conditions in the lab (control). Four plates containing each strain were exposed in each condition: two plates had the appropriate positive-control mutagen for each strain included in the top agar and two plates did not. Plates were exposed to either E, M, EM, or control conditions at room temperature for 48 hr. and then incubated an additional 24 hr. at 37 deg. C. The plates containing mutagen in the top agar showed an increased number of colonies consistent with mutagenesis. However, the rate of mutation in the S. typhimurium strains TA97a, TA98, TA100, and TA102 in either the presence or absence of mutagen was not affected by 48 hr. exposure at room temperature to E, M, or EM fields at 60, 600, or 6000 Hz.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
no_effect
Population
Salmonella typhimurium tester strains (TA97a, TA98, TA100, TA102) in Ames assay plates
Sample size
—
Exposure
ELF · 48 hr exposure at room temperature; then incubated 24 hr at 37°C
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Exposure of four Salmonella typhimurium tester strains to alternating electric fields (300 V/in.), magnetic fields (0.3 mT), or combined fields at 60, 600, or 6000 Hz for 48 hours did not affect mutation rates compared with control conditions, either with or without added positive-control mutagens.

Outcomes measured

  • Mutation rate / mutagenicity in Ames assay (colony counts)
View raw extracted JSON
{
    "study_type": "in_vitro",
    "exposure": {
        "band": "ELF",
        "source": null,
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "48 hr exposure at room temperature; then incubated 24 hr at 37°C"
    },
    "population": "Salmonella typhimurium tester strains (TA97a, TA98, TA100, TA102) in Ames assay plates",
    "sample_size": null,
    "outcomes": [
        "Mutation rate / mutagenicity in Ames assay (colony counts)"
    ],
    "main_findings": "Exposure of four Salmonella typhimurium tester strains to alternating electric fields (300 V/in.), magnetic fields (0.3 mT), or combined fields at 60, 600, or 6000 Hz for 48 hours did not affect mutation rates compared with control conditions, either with or without added positive-control mutagens.",
    "effect_direction": "no_effect",
    "limitations": [],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "Ames assay",
        "genotoxicity",
        "mutagenicity",
        "Salmonella typhimurium",
        "ELF EMF",
        "electric field",
        "magnetic field",
        "60 Hz",
        "600 Hz",
        "6000 Hz",
        "0.3 mT",
        "300 V/in",
        "Helmholtz coils",
        "parallel plate electrodes"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.