The effect of extremely low frequency electromagnetic fields (ELF-EMF) on the frequency of micronuclei and sister chromatid exchange in human lymphocytes induced by benzo(a)pyrene.

PAPER pubmed Toxicology letters 2003 In vitro study Effect: mixed Evidence: Low

Abstract

The interaction of extremely low frequency electromagnetic fields (ELF-EMF) on the frequency of micronuclei (MN) and sister chromatid exchange (SCE) induced by benzo(a)pyrene (BP) in human lymphocytes was examined. A 60 Hz ELF-EMF of 0.8 mT field strength was applied either alone or with the tumor initiator, BP for 24 h. The frequencies of MN and SCE induced by BP increased in a dose-dependent manner. The co-exposure of cells to BP and 0.8 mT ELF-EMF for 24 h, followed by BP exposure for 48 h led to significant increases in the frequencies of MN and SCE compared to BP treatment for 72 h alone (P<0.05), but no significant difference was observed between field exposed and sham exposed control cells. The obtained results suggest that low density ELF-EMF could act as an enhancer of the initiation process of BP rather than as an initiator of mutagenic effects in human lymphocytes.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
mixed
Population
Human lymphocytes (cells)
Sample size
—
Exposure
ELF · 0.06 MHz · 24 h (ELF-EMF applied alone or with BP); co-exposure 24 h then BP 48 h
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

A 60 Hz, 0.8 mT ELF-EMF alone did not significantly change MN or SCE compared with sham-exposed controls. Co-exposure to BP and ELF-EMF for 24 h followed by BP exposure for 48 h significantly increased MN and SCE frequencies compared with BP exposure for 72 h alone (P<0.05).

Outcomes measured

  • Micronuclei (MN) frequency
  • Sister chromatid exchange (SCE) frequency

Limitations

  • Sample size not reported in abstract
  • In vitro study in human lymphocytes; generalizability to in vivo outcomes not established
  • Exposure conditions limited to 60 Hz at 0.8 mT and specific co-exposure timing with benzo(a)pyrene
View raw extracted JSON
{
    "study_type": "in_vitro",
    "exposure": {
        "band": "ELF",
        "source": null,
        "frequency_mhz": 0.059999999999999997779553950749686919152736663818359375,
        "sar_wkg": null,
        "duration": "24 h (ELF-EMF applied alone or with BP); co-exposure 24 h then BP 48 h"
    },
    "population": "Human lymphocytes (cells)",
    "sample_size": null,
    "outcomes": [
        "Micronuclei (MN) frequency",
        "Sister chromatid exchange (SCE) frequency"
    ],
    "main_findings": "A 60 Hz, 0.8 mT ELF-EMF alone did not significantly change MN or SCE compared with sham-exposed controls. Co-exposure to BP and ELF-EMF for 24 h followed by BP exposure for 48 h significantly increased MN and SCE frequencies compared with BP exposure for 72 h alone (P<0.05).",
    "effect_direction": "mixed",
    "limitations": [
        "Sample size not reported in abstract",
        "In vitro study in human lymphocytes; generalizability to in vivo outcomes not established",
        "Exposure conditions limited to 60 Hz at 0.8 mT and specific co-exposure timing with benzo(a)pyrene"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "extremely low frequency",
        "ELF-EMF",
        "60 Hz",
        "0.8 mT",
        "human lymphocytes",
        "micronuclei",
        "sister chromatid exchange",
        "benzo(a)pyrene",
        "co-exposure",
        "genotoxicity"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.