Acute effects of low-frequency electromagnetic fields on leukocyte-endothelial interactions in vivo.

PAPER pubmed In vivo (Athens, Greece) 2004 Animal study Effect: mixed Evidence: Low

Abstract

BACKGROUND: To clarify the effect of extremely low frequency electromagnetic field (ELF-EMF) on the microcirculatory system, acute effects on leukocyte-endothelium interactions resulting from ELF-EMF exposure were examined with conscious BALB/c mice by means of a dorsal skinfold chamber. MATERIALS AND METHODS: The fluorescent dye, rhodamine 6G, was injected into the caudal vein to visualize leukocytes in vivo and to analyze leukocyte-endothelium interactions. Mice were exposed in vivo to 50 Hz linear sinusoidal wave EMF at magnetic flux densities of 3, 10 or 30 mT, for 30 minutes. RESULTS: The mean velocity of free flowing leukocytes in the center stream of venules revealed no distinct changes following exposure. However, at a flux density of 30 mT, the number of adherent leukocytes, defined as the total number of rolling and endothelium-adhering leukocytes, increased significantly following ELF-EMF exposure (p<0.05); no significant differences in adherent cell numbers were found in the 3 mT and 10 mT exposure groups or sham controls comparing pre- and post-exposure periods. CONCLUSION: These results demonstrated that high magnetic flux densities of ELF-EMF had an effect on leukocyte-endothelium interactions and indicated that a threshold level for this phenomenon exists in the range of 10-30 mT under these experimental conditions.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Conscious BALB/c mice (dorsal skinfold chamber model)
Sample size
—
Exposure
ELF · 0.05 MHz · 30 minutes
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Exposure to 50 Hz sinusoidal EMF at 30 mT for 30 minutes significantly increased the number of adherent leukocytes (rolling + endothelium-adhering) compared with pre-exposure (p<0.05). No distinct changes were observed in mean velocity of free-flowing leukocytes, and no significant differences in adherent leukocyte numbers were found at 3 mT or 10 mT or in sham controls.

Outcomes measured

  • Leukocyte velocity in venules (free-flowing leukocytes)
  • Number of adherent leukocytes (rolling + endothelium-adhering)
  • Leukocyte-endothelium interactions in vivo

Limitations

  • Sample size not reported in the abstract
  • Acute exposure only (30 minutes); no longer-term outcomes reported
  • Animal model; generalizability to humans not addressed
  • Exposure source/setup details beyond waveform, frequency, and flux density not provided in the abstract
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "ELF",
        "source": null,
        "frequency_mhz": 0.05000000000000000277555756156289135105907917022705078125,
        "sar_wkg": null,
        "duration": "30 minutes"
    },
    "population": "Conscious BALB/c mice (dorsal skinfold chamber model)",
    "sample_size": null,
    "outcomes": [
        "Leukocyte velocity in venules (free-flowing leukocytes)",
        "Number of adherent leukocytes (rolling + endothelium-adhering)",
        "Leukocyte-endothelium interactions in vivo"
    ],
    "main_findings": "Exposure to 50 Hz sinusoidal EMF at 30 mT for 30 minutes significantly increased the number of adherent leukocytes (rolling + endothelium-adhering) compared with pre-exposure (p<0.05). No distinct changes were observed in mean velocity of free-flowing leukocytes, and no significant differences in adherent leukocyte numbers were found at 3 mT or 10 mT or in sham controls.",
    "effect_direction": "mixed",
    "limitations": [
        "Sample size not reported in the abstract",
        "Acute exposure only (30 minutes); no longer-term outcomes reported",
        "Animal model; generalizability to humans not addressed",
        "Exposure source/setup details beyond waveform, frequency, and flux density not provided in the abstract"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "extremely low frequency",
        "ELF-EMF",
        "50 Hz",
        "magnetic flux density",
        "3 mT",
        "10 mT",
        "30 mT",
        "microcirculation",
        "leukocyte-endothelial interactions",
        "rolling",
        "adhesion",
        "dorsal skinfold chamber",
        "BALB/c mice"
    ],