Acute effects of low-frequency electromagnetic fields on leukocyte-endothelial interactions in vivo.
Abstract
BACKGROUND: To clarify the effect of extremely low frequency electromagnetic field (ELF-EMF) on the microcirculatory system, acute effects on leukocyte-endothelium interactions resulting from ELF-EMF exposure were examined with conscious BALB/c mice by means of a dorsal skinfold chamber. MATERIALS AND METHODS: The fluorescent dye, rhodamine 6G, was injected into the caudal vein to visualize leukocytes in vivo and to analyze leukocyte-endothelium interactions. Mice were exposed in vivo to 50 Hz linear sinusoidal wave EMF at magnetic flux densities of 3, 10 or 30 mT, for 30 minutes. RESULTS: The mean velocity of free flowing leukocytes in the center stream of venules revealed no distinct changes following exposure. However, at a flux density of 30 mT, the number of adherent leukocytes, defined as the total number of rolling and endothelium-adhering leukocytes, increased significantly following ELF-EMF exposure (p<0.05); no significant differences in adherent cell numbers were found in the 3 mT and 10 mT exposure groups or sham controls comparing pre- and post-exposure periods. CONCLUSION: These results demonstrated that high magnetic flux densities of ELF-EMF had an effect on leukocyte-endothelium interactions and indicated that a threshold level for this phenomenon exists in the range of 10-30 mT under these experimental conditions.
AI evidence extraction
Main findings
Exposure to 50 Hz sinusoidal EMF at 30 mT for 30 minutes significantly increased the number of adherent leukocytes (rolling + endothelium-adhering) compared with pre-exposure (p<0.05). No distinct changes were observed in mean velocity of free-flowing leukocytes, and no significant differences in adherent leukocyte numbers were found at 3 mT or 10 mT or in sham controls.
Outcomes measured
- Leukocyte velocity in venules (free-flowing leukocytes)
- Number of adherent leukocytes (rolling + endothelium-adhering)
- Leukocyte-endothelium interactions in vivo
Limitations
- Sample size not reported in the abstract
- Acute exposure only (30 minutes); no longer-term outcomes reported
- Animal model; generalizability to humans not addressed
- Exposure source/setup details beyond waveform, frequency, and flux density not provided in the abstract
View raw extracted JSON
{
"study_type": "animal",
"exposure": {
"band": "ELF",
"source": null,
"frequency_mhz": 0.05000000000000000277555756156289135105907917022705078125,
"sar_wkg": null,
"duration": "30 minutes"
},
"population": "Conscious BALB/c mice (dorsal skinfold chamber model)",
"sample_size": null,
"outcomes": [
"Leukocyte velocity in venules (free-flowing leukocytes)",
"Number of adherent leukocytes (rolling + endothelium-adhering)",
"Leukocyte-endothelium interactions in vivo"
],
"main_findings": "Exposure to 50 Hz sinusoidal EMF at 30 mT for 30 minutes significantly increased the number of adherent leukocytes (rolling + endothelium-adhering) compared with pre-exposure (p<0.05). No distinct changes were observed in mean velocity of free-flowing leukocytes, and no significant differences in adherent leukocyte numbers were found at 3 mT or 10 mT or in sham controls.",
"effect_direction": "mixed",
"limitations": [
"Sample size not reported in the abstract",
"Acute exposure only (30 minutes); no longer-term outcomes reported",
"Animal model; generalizability to humans not addressed",
"Exposure source/setup details beyond waveform, frequency, and flux density not provided in the abstract"
],
"evidence_strength": "low",
"confidence": 0.7800000000000000266453525910037569701671600341796875,
"peer_reviewed_likely": "yes",
"keywords": [
"extremely low frequency",
"ELF-EMF",
"50 Hz",
"magnetic flux density",
"3 mT",
"10 mT",
"30 mT",
"microcirculation",
"leukocyte-endothelial interactions",
"rolling",
"adhesion",
"dorsal skinfold chamber",
"BALB/c mice"
],
"suggested_hubs": []
}
AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.