Share
𝕏 Facebook LinkedIn

Pulsed electromagnetic fields accelerate apoptotic rate in osteoclasts.

PAPER pubmed Connective tissue research 2006 In vitro study Effect: mixed Evidence: Low

Abstract

Selective control of cell function by applying specifically configured, low-energy, time-varying electromagnetic fields (EMF) has added a new, exciting dimension to biology and medicine. However, the mechanism involved is less clear. In our study, we investigated the effect of pulsed electromagnetic fields (PEMF) on induction of osteoclasts apoptosis. A statistically significant increase of apoptotic rate in osteoclasts (48 hr after isolation) was found when exposed to 7.5 Hz PEMF with induced electric fields intensity of 3.0 muv/cm for 8 (105%, p < 0.001) and 16 hr (30%, p < 0.05). However, exposure of osteoclasts to PEMF for only 1 hr showed no statistically significant differences. These findings suggest that PEMF have the ability to speed up apoptosis of osteoclasts derived from primary osteoblasts and bone marrow cells cocultures. This in vitro study, therefore, could be considered as groundwork for in vivo PEMF applications on some osteoclasts-associated bone diseases such as osteoporosis.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
mixed
Population
—
Sample size
—
Exposure
ELF pulsed electromagnetic fields (PEMF) · 1 hr, 8 hr, 16 hr exposures; apoptosis assessed 48 hr after isolation
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Osteoclasts exposed to 7.5 Hz PEMF (induced electric field intensity 3.0 mV/cm) showed a statistically significant increase in apoptotic rate after 8 hr (105%, p<0.001) and 16 hr (30%, p<0.05) exposures, while 1 hr exposure showed no statistically significant difference.

Outcomes measured

  • Osteoclast apoptosis (apoptotic rate)

Limitations

  • In vitro study (mechanism and in vivo relevance not established in abstract)
  • Sample size not reported in abstract
  • Exposure metrics limited to frequency and induced electric field intensity; other dosimetry details not provided
View raw extracted JSON
{
    "study_type": "in_vitro",
    "exposure": {
        "band": "ELF",
        "source": "pulsed electromagnetic fields (PEMF)",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "1 hr, 8 hr, 16 hr exposures; apoptosis assessed 48 hr after isolation"
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Osteoclast apoptosis (apoptotic rate)"
    ],
    "main_findings": "Osteoclasts exposed to 7.5 Hz PEMF (induced electric field intensity 3.0 mV/cm) showed a statistically significant increase in apoptotic rate after 8 hr (105%, p<0.001) and 16 hr (30%, p<0.05) exposures, while 1 hr exposure showed no statistically significant difference.",
    "effect_direction": "mixed",
    "limitations": [
        "In vitro study (mechanism and in vivo relevance not established in abstract)",
        "Sample size not reported in abstract",
        "Exposure metrics limited to frequency and induced electric field intensity; other dosimetry details not provided"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "pulsed electromagnetic fields",
        "PEMF",
        "7.5 Hz",
        "induced electric field",
        "3.0 mV/cm",
        "osteoclasts",
        "apoptosis",
        "in vitro",
        "bone marrow cells",
        "coculture",
        "osteoporosis"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments