Share
𝕏 Facebook LinkedIn

Vitamin C and Vitamin E Protected B and Balb/c-3T3 Cells from Apoptosis Induced by Intermittent 50Hz ELF-EMF Radiation.

PAPER pubmed Iranian journal of public health 2017 In vitro study Effect: mixed Evidence: Low

Abstract

BACKGROUND: The extremely low-frequency electromagnetic field (ELF-EMF), mainly emitted by electric transmission lines and household electronic appliances, is becoming a worldwide health risk. It is imperative to investigate the biological impacts of ELF-EMF and to identify products that are resistant to the radiation from 50 Hz ELF-EMF. In this study, we investigated the biological impacts of apoptosis caused by 50 Hz Power line ELF-EMF and the protective effects of Vit C and Vit E. METHODS: We conducted this study in Beijing, China in 2013. B and Balb/c-3T3 cells were divided into a sham group, an expo group and 3 expo groups in which the cells were preincubated with various concentrations of Vit C and Vit E. Then, all of the cells were exposed to 50 Hz Power line ELF-EMF and examined for apoptosis. The cells were collected for apoptosis detection after exposure. RESULTS: The percent of cells that undergoing apoptosis and preincubated with various concentrations of Vit C and Vit E were significantly lower than in the Expo group. CONCLUSION: Vit C and Vit E exert significant protective effects from 50 Hz ELF-EMF radiation. The optimal protective concentrations of Vit C and Vit E are 10 μmol/L and 25 μmol/L, respectively. The protective effect of vitamins was more apparent for Balb/c-3T3 cells than B cells.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
mixed
Population
—
Sample size
—
Exposure
ELF power line · 0.05 MHz
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

After exposure to 50 Hz power line ELF-EMF, cells preincubated with various concentrations of vitamin C and vitamin E had significantly lower percentages of apoptosis than the exposed (non-vitamin) group. The abstract reports optimal protective concentrations of 10 μmol/L (vitamin C) and 25 μmol/L (vitamin E), with a more apparent protective effect in Balb/c-3T3 cells than B cells.

Outcomes measured

  • Apoptosis in B cells
  • Apoptosis in Balb/c-3T3 cells
  • Protective effects of vitamin C preincubation
  • Protective effects of vitamin E preincubation

Limitations

  • Exposure intensity and duration are not reported in the abstract.
  • No sample size or number of replicates is provided in the abstract.
  • Only in vitro cell models were studied; findings may not generalize beyond these cell lines.
  • Details of apoptosis assay/methods are not described in the abstract.

Suggested hubs

  • occupational-exposure (0.2)
    Exposure described as 50 Hz power line ELF-EMF; relevant to power-line related exposures, though the study is in vitro.
View raw extracted JSON
{
    "study_type": "in_vitro",
    "exposure": {
        "band": "ELF",
        "source": "power line",
        "frequency_mhz": 0.05000000000000000277555756156289135105907917022705078125,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Apoptosis in B cells",
        "Apoptosis in Balb/c-3T3 cells",
        "Protective effects of vitamin C preincubation",
        "Protective effects of vitamin E preincubation"
    ],
    "main_findings": "After exposure to 50 Hz power line ELF-EMF, cells preincubated with various concentrations of vitamin C and vitamin E had significantly lower percentages of apoptosis than the exposed (non-vitamin) group. The abstract reports optimal protective concentrations of 10 μmol/L (vitamin C) and 25 μmol/L (vitamin E), with a more apparent protective effect in Balb/c-3T3 cells than B cells.",
    "effect_direction": "mixed",
    "limitations": [
        "Exposure intensity and duration are not reported in the abstract.",
        "No sample size or number of replicates is provided in the abstract.",
        "Only in vitro cell models were studied; findings may not generalize beyond these cell lines.",
        "Details of apoptosis assay/methods are not described in the abstract."
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "ELF-EMF",
        "50 Hz",
        "power line",
        "apoptosis",
        "vitamin C",
        "vitamin E",
        "B cells",
        "Balb/c-3T3",
        "in vitro"
    ],
    "suggested_hubs": [
        {
            "slug": "occupational-exposure",
            "weight": 0.200000000000000011102230246251565404236316680908203125,
            "reason": "Exposure described as 50 Hz power line ELF-EMF; relevant to power-line related exposures, though the study is in vitro."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.