Share
𝕏 Facebook LinkedIn

Effect of electromagnetic fields and antioxidants on the trace element content of rat teeth.

PAPER pubmed Drug design, development and therapy 2017 Animal study Effect: mixed Evidence: Low

Abstract

The purpose of this study was to examine the possible effect of extremely low-frequency electromagnetic fields (ELF-EMFs), from a high-voltage source, on rat teeth in terms of changes in trace elements (TEs) and the effect of antioxidants (melatonin [MLT] and [GL]) in counteracting these effects. We used adult male Wistar albino rats with a mean weight of 250-300 g and divided the rats into eight groups. The groups were subjected to an ELF-EMF that was applied with a high-voltage line for 8 hours/day for 26 days (Groups I, II, and III) or 52 days (Groups V, VI, and VII). Groups IV and VIII were the 26- and 52-day control/sham groups, respectively. Groups II and VI were treated with GL, and Groups III and VII were treated with MLT. MLT and GL were administered daily based on the weight of the animals and appropriate standards. At the end of the study, the rats were euthanized, and their anterior teeth were extracted. The teeth were preserved in pure water before evaluating the major TEs. At the end of the study, TE concentrations (in mg/kg) were assessed in the control and test groups. Compared with Group V, statistically significant differences in the concentrations of zinc (Zn) and strontium (Sr) were found for Group VII (ELF-EMF + MLT) (<0.05). Therefore, ELF-EMF exposure can change the content of certain TEs in teeth and, after administering MLT and GL, the values of some of the TEs return to normal.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Adult male Wistar albino rats (250–300 g)
Sample size
—
Exposure
ELF high-voltage line · 8 hours/day for 26 days or 52 days
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Rats were exposed to ELF-EMF from a high-voltage line (8 h/day) for 26 or 52 days, with some groups receiving antioxidants (melatonin or GL). Statistically significant differences in tooth Zn and Sr concentrations were reported for the 52-day ELF-EMF + melatonin group compared with the 52-day comparison group (Group V) (P<0.05). The abstract states that ELF-EMF exposure can change certain tooth trace elements and that after administering melatonin and GL, some trace element values return to normal.

Outcomes measured

  • Trace element concentrations in rat anterior teeth (mg/kg)
  • Zinc (Zn) concentration
  • Strontium (Sr) concentration

Limitations

  • Sample size not reported in the abstract
  • ELF-EMF exposure parameters (e.g., field strength, frequency) not reported in the abstract
  • Unclear which specific group(s) serve as the primary control for each comparison (e.g., definition of Group V not described in the abstract)
  • Only select trace elements (Zn, Sr) are explicitly mentioned as significantly different; full results not provided in the abstract

Suggested hubs

  • occupational-exposure (0.35)
    Exposure source described as a high-voltage line (power-line/ELF context).
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "ELF",
        "source": "high-voltage line",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "8 hours/day for 26 days or 52 days"
    },
    "population": "Adult male Wistar albino rats (250–300 g)",
    "sample_size": null,
    "outcomes": [
        "Trace element concentrations in rat anterior teeth (mg/kg)",
        "Zinc (Zn) concentration",
        "Strontium (Sr) concentration"
    ],
    "main_findings": "Rats were exposed to ELF-EMF from a high-voltage line (8 h/day) for 26 or 52 days, with some groups receiving antioxidants (melatonin or GL). Statistically significant differences in tooth Zn and Sr concentrations were reported for the 52-day ELF-EMF + melatonin group compared with the 52-day comparison group (Group V) (P<0.05). The abstract states that ELF-EMF exposure can change certain tooth trace elements and that after administering melatonin and GL, some trace element values return to normal.",
    "effect_direction": "mixed",
    "limitations": [
        "Sample size not reported in the abstract",
        "ELF-EMF exposure parameters (e.g., field strength, frequency) not reported in the abstract",
        "Unclear which specific group(s) serve as the primary control for each comparison (e.g., definition of Group V not described in the abstract)",
        "Only select trace elements (Zn, Sr) are explicitly mentioned as significantly different; full results not provided in the abstract"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "ELF-EMF",
        "high-voltage line",
        "rat teeth",
        "trace elements",
        "zinc",
        "strontium",
        "melatonin",
        "antioxidants",
        "Wistar rats"
    ],
    "suggested_hubs": [
        {
            "slug": "occupational-exposure",
            "weight": 0.34999999999999997779553950749686919152736663818359375,
            "reason": "Exposure source described as a high-voltage line (power-line/ELF context)."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.