Share
𝕏 Facebook LinkedIn

Non-conductive and miniature fiber-optic imaging system for real-time detection of neuronal activity in time-varying electromagnetic fields.

PAPER pubmed Biosensors & bioelectronics 2017 Other Effect: mixed Evidence: Low

Abstract

Establishing an appropriate threshold value for neuronal modulation by time-varying electromagnetic field (EMF) exposure is important for developing international guidelines to protect against the potential health effects, and to design a variety of medical devices. However, it is technically difficult to achieve real-time detection of neuronal activity under repetitive and long-term exposure to EMF. For this purpose, we developed a non-conductive, miniature, and flexible fiber-optic imaging system that does not affect the electromagnetic noise, induction heating, or vibration in a high-intensity and repetitive time-varying EMF exposure. Using the proposed system, we succeeded at real-time detection of spontaneous Ca oscillations in single neuronal and glial cells, as well as synchronized bursting activities of multiple neuronal networks at a micrometer-scale and millisecond-order spatiotemporal resolution during long-term EMF exposure (sinusoidal wave, 20kHz, 8.6mT, >30min). The results indicated that short-term (<5min) exposure-related neuronal modulation was not detectable; however, long-term (15-30min) exposure was observed to depress neuronal activities. In addition, the simultaneous and real-time recording of neuronal activity and the environmental temperature revealed that the neuronal modulation was accompanied by a 0.5-1°C rise in the temperature of the culture medium induced by the heat generation of exposure coils. These findings suggest that our real-time imaging system can be used for precise evaluation of the threshold values and clarification of the mechanisms of neuronal modulation induced by time-varying EMF exposure.

AI evidence extraction

At a glance
Study type
Other
Effect direction
mixed
Population
Cultured neuronal and glial cells; neuronal networks (in vitro)
Sample size
—
Exposure
ELF other · 0.02 MHz · >30min (with comparisons: <5min; 15–30min)
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

A non-conductive miniature fiber-optic imaging system enabled real-time recording of calcium oscillations and network bursting during sinusoidal 20 kHz, 8.6 mT EMF exposure (>30 min). Short-term exposure (<5 min) showed no detectable neuronal modulation, while longer exposure (15–30 min) was associated with depressed neuronal activity and a concurrent 0.5–1°C rise in culture-medium temperature attributed to heating from exposure coils.

Outcomes measured

  • Real-time detection of spontaneous Ca oscillations in single neuronal and glial cells
  • Synchronized bursting activities of multiple neuronal networks
  • Neuronal activity modulation (depression) during EMF exposure
  • Culture medium temperature change during exposure

Limitations

  • In vitro cell culture model; generalizability to humans not addressed in abstract
  • Sample size not reported in abstract
  • Observed modulation accompanied by temperature rise, suggesting potential thermal confounding from exposure coils

Suggested hubs

  • who-icnirp (0.42)
    Abstract discusses establishing threshold values for neuronal modulation to inform international guidelines for EMF exposure.
View raw extracted JSON
{
    "study_type": "other",
    "exposure": {
        "band": "ELF",
        "source": "other",
        "frequency_mhz": 0.0200000000000000004163336342344337026588618755340576171875,
        "sar_wkg": null,
        "duration": ">30min (with comparisons: <5min; 15–30min)"
    },
    "population": "Cultured neuronal and glial cells; neuronal networks (in vitro)",
    "sample_size": null,
    "outcomes": [
        "Real-time detection of spontaneous Ca oscillations in single neuronal and glial cells",
        "Synchronized bursting activities of multiple neuronal networks",
        "Neuronal activity modulation (depression) during EMF exposure",
        "Culture medium temperature change during exposure"
    ],
    "main_findings": "A non-conductive miniature fiber-optic imaging system enabled real-time recording of calcium oscillations and network bursting during sinusoidal 20 kHz, 8.6 mT EMF exposure (>30 min). Short-term exposure (<5 min) showed no detectable neuronal modulation, while longer exposure (15–30 min) was associated with depressed neuronal activity and a concurrent 0.5–1°C rise in culture-medium temperature attributed to heating from exposure coils.",
    "effect_direction": "mixed",
    "limitations": [
        "In vitro cell culture model; generalizability to humans not addressed in abstract",
        "Sample size not reported in abstract",
        "Observed modulation accompanied by temperature rise, suggesting potential thermal confounding from exposure coils"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "fiber-optic imaging",
        "non-conductive",
        "real-time detection",
        "neuronal activity",
        "glial cells",
        "calcium oscillations",
        "network bursting",
        "time-varying electromagnetic fields",
        "20 kHz",
        "8.6 mT",
        "temperature rise",
        "induction heating"
    ],
    "suggested_hubs": [
        {
            "slug": "who-icnirp",
            "weight": 0.419999999999999984456877655247808434069156646728515625,
            "reason": "Abstract discusses establishing threshold values for neuronal modulation to inform international guidelines for EMF exposure."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.