Share
𝕏 Facebook LinkedIn

Effect of extremely low frequency electromagnetic fields on bacterial membrane.

PAPER pubmed International journal of radiation biology 2016 In vitro study Effect: mixed Evidence: Low

Abstract

PURPOSE: The effect of extremely low frequency electromagnetic fields (ELF-EMF) on bacteria has attracted attention due to its potential for beneficial uses. This research aimed to determine the effect of ELF-EMF on bacterial membrane namely the membrane potential, surface potential, hydrophobicity, respiratory activity and growth. MATERIALS AND METHODS: Gram-positive Staphylococcus aureus and Gram-negative Escherichia coli were subjected to ELF-EMF, 50 Hz, 1 mT for 2 h. Membrane potential was determined by fluorescence spectroscopy with or without EDTA (Ethylenediaminetetraacetic acid) with DisC3(5) (3,3-dipropylthiacarbocyanine iodide), zeta potential measurements were performed by electrophoretic mobility, hydrophobicity of the membrane was measured with MATH (Microbial Adhesion to Hydrocarbons) test, respiratory activity was determined with CTC (5-Cyano-2,3-ditolyl tetrazolium chloride), colony forming unit (CFU) and DAPI (4',6-diamidino-2-phenylindole, dihydrochloride) was used for growth determinations. RESULTS: ELF-EMF caused changes in physicochemical properties of both Gram-positive and Gram-negative bacteria. Hyperpolarization was seen in S. aureus and EDTA-treated E. coli. Surface potential showed a positive shift in S. aureus contrariwise to the negative shift seen in EDTA-untreated E. coli. Respiratory activity increased in both bacteria. A slight decrease in growth was observed. CONCLUSION: These results show that ELF-EMF affects the crucial physicochemical processes in both Gram-positive and Gram-negative bacteria which need further research.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
mixed
Population
—
Sample size
—
Exposure
ELF · 0.05 MHz · 2 h
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Exposure to 50 Hz, 1 mT ELF-EMF for 2 h was associated with changes in physicochemical properties in both Staphylococcus aureus and Escherichia coli. Hyperpolarization was reported in S. aureus and in EDTA-treated E. coli; surface potential shifted positively in S. aureus and negatively in EDTA-untreated E. coli. Respiratory activity increased in both bacteria, and a slight decrease in growth was observed.

Outcomes measured

  • Bacterial membrane potential
  • Bacterial surface (zeta) potential
  • Bacterial membrane hydrophobicity
  • Bacterial respiratory activity
  • Bacterial growth (CFU, DAPI)

Limitations

  • Sample size not reported in abstract
  • In vitro bacterial model; generalizability to in vivo/clinical settings not addressed
  • Exposure conditions limited to a single frequency (50 Hz), field strength (1 mT), and duration (2 h)
View raw extracted JSON
{
    "study_type": "in_vitro",
    "exposure": {
        "band": "ELF",
        "source": null,
        "frequency_mhz": 0.05000000000000000277555756156289135105907917022705078125,
        "sar_wkg": null,
        "duration": "2 h"
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Bacterial membrane potential",
        "Bacterial surface (zeta) potential",
        "Bacterial membrane hydrophobicity",
        "Bacterial respiratory activity",
        "Bacterial growth (CFU, DAPI)"
    ],
    "main_findings": "Exposure to 50 Hz, 1 mT ELF-EMF for 2 h was associated with changes in physicochemical properties in both Staphylococcus aureus and Escherichia coli. Hyperpolarization was reported in S. aureus and in EDTA-treated E. coli; surface potential shifted positively in S. aureus and negatively in EDTA-untreated E. coli. Respiratory activity increased in both bacteria, and a slight decrease in growth was observed.",
    "effect_direction": "mixed",
    "limitations": [
        "Sample size not reported in abstract",
        "In vitro bacterial model; generalizability to in vivo/clinical settings not addressed",
        "Exposure conditions limited to a single frequency (50 Hz), field strength (1 mT), and duration (2 h)"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "extremely low frequency",
        "ELF-EMF",
        "50 Hz",
        "1 mT",
        "Staphylococcus aureus",
        "Escherichia coli",
        "membrane potential",
        "zeta potential",
        "hydrophobicity",
        "respiratory activity",
        "growth",
        "EDTA"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.