Share
𝕏 Facebook LinkedIn

Effects of extremely low frequency electromagnetic field (50 Hz) on pentylenetetrazol-induced seizures in mice.

PAPER pubmed Acta neurologica Belgica 2013 Animal study Effect: mixed Evidence: Low

Abstract

The electromagnetic fields (EMF) have various behavioral and biological effects on human body. There are growing concerns about the consequences of exposure to EMF. However, some studies have shown beneficial effects of these waves on human. In this paper, we study the effect of acute, sub acute and long-term exposure to 50 Hz, 0.1 mT magnetic fields (MF) on the seizure induction threshold in mice. 64 mice are used and divided into four groups. Eight mice in any group were selected to be exposed to MF for specific duration and the others were used as a control group. The duration of the applied exposures was as follows: (1) 1 day (acute), (2) 3 days (sub acute), (3) 2 weeks (sub acute), (4) 1 month (long term). The mice were exposed 2 h for a day. After exposure, the pentylentetrazol (PTZ) is injected to the mice to induce seizure and the needed dose for the seizure induction threshold is measured. In the acute exposure, the threshold to induce seizure in the exposed and sham-exposed groups was 44.25 and 46.5 mg, respectively, while the difference was not significant (p value = 0.5). In the sub acute exposure (3 days), the mean amount of drug to induce seizure was 47.38 mg in the exposed and 43.88 mg in the sham-exposed groups, however, the difference was not significant (p value = 0.3). The results were 52.38 and 46.75 mg after 2 weeks of exposure which were not significantly different either (p value = 0.2). After 1 month of exposure to MF, the threshold for the induction of seizure was significantly increased (p value < 0.05). The mean dosage to induce seizure in the exposed and control group was 54.3 and 45.75 mg, respectively. However, considering the p value, the difference in the seizure induction threshold between the exposed and sham-exposed groups after acute and sub acute exposure was not significant, analyzing the effects of acute, sub acute and long-term exposures totally indicates that increasing the exposure time increases the seizure induction threshold.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Mice
Sample size
64
Exposure
ELF · 5.0E-5 MHz · Acute (1 day), sub-acute (3 days; 2 weeks), long-term (1 month); 2 h/day
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Mice exposed to 50 Hz, 0.1 mT magnetic fields for 1 day, 3 days, or 2 weeks showed no statistically significant differences in PTZ dose required to induce seizures compared with sham-exposed controls. After 1 month of exposure, the seizure induction threshold was significantly increased in exposed mice (mean 54.3 mg vs 45.75 mg in controls; p<0.05).

Outcomes measured

  • Pentylenetetrazol (PTZ)-induced seizure induction threshold (dose required to induce seizure)

Limitations

  • Exposure source/setup details not described in the abstract (e.g., field uniformity, sham conditions).
  • Outcome reporting is limited to mean PTZ doses and p-values; variability measures are not provided in the abstract.
  • Only one field strength (0.1 mT) and one frequency (50 Hz) are studied.
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "ELF",
        "source": null,
        "frequency_mhz": 5.00000000000000023960868011929647991564706899225711822509765625e-5,
        "sar_wkg": null,
        "duration": "Acute (1 day), sub-acute (3 days; 2 weeks), long-term (1 month); 2 h/day"
    },
    "population": "Mice",
    "sample_size": 64,
    "outcomes": [
        "Pentylenetetrazol (PTZ)-induced seizure induction threshold (dose required to induce seizure)"
    ],
    "main_findings": "Mice exposed to 50 Hz, 0.1 mT magnetic fields for 1 day, 3 days, or 2 weeks showed no statistically significant differences in PTZ dose required to induce seizures compared with sham-exposed controls. After 1 month of exposure, the seizure induction threshold was significantly increased in exposed mice (mean 54.3 mg vs 45.75 mg in controls; p<0.05).",
    "effect_direction": "mixed",
    "limitations": [
        "Exposure source/setup details not described in the abstract (e.g., field uniformity, sham conditions).",
        "Outcome reporting is limited to mean PTZ doses and p-values; variability measures are not provided in the abstract.",
        "Only one field strength (0.1 mT) and one frequency (50 Hz) are studied."
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "extremely low frequency",
        "ELF",
        "50 Hz",
        "magnetic field",
        "0.1 mT",
        "mice",
        "pentylenetetrazol",
        "PTZ",
        "seizure threshold",
        "acute exposure",
        "sub-acute exposure",
        "long-term exposure"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.