Share
𝕏 Facebook LinkedIn

[Effect of electromagnetic field of extremely low frequency on ATPase activity of actomyosin].

PAPER pubmed Ukrains'kyi biokhimichnyi zhurnal (1999 ) 2012 In vitro study Effect: mixed Evidence: Low

Abstract

The Mg2+/Ca2+ and K(+)-ATPase actomyosin activity of rabbit skeletal muscle was evaluated by the Fiske-Subbarow method during a five-hour exposition of protein solutions in electromagnetic field of extremely low frequency of 8 Hz and 25 microT induction. The results of the study of the ATPase activity of actomyosin upon electromagnetic exposure have shown statistically significant changes that are characterized by a rather complex time dynamics. After 1, 2 and 4 hours of exposure of protein solutions the effect of ELF EMF exposure inhibits the ATPase activity compared to control samples, which are not exposed to the magnetic field. By the third and fifth hours of exposure to the electromagnetic field, there is a significant increase in the ATPase activity of actomyosin. It should be noted that a similar pattern of change in enzyme activity was universal, both for the environment by Mg2+ and Ca2+, and in the absence of these ions in the buffer. This can evidence for Ca(2+)-independent ways of the infuence of electromagnetic field (EMP) on biologic objects. In our opinion, the above effects are explained by EMP influence on the dynamic properties of actomyosin solutions, which are based on the processes of spontaneous dynamic formation of structure.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
mixed
Population
Rabbit skeletal muscle actomyosin protein solutions (in vitro)
Sample size
—
Exposure
ELF other · 8.0E-6 MHz · 5 hours
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

During 5-hour exposure of rabbit skeletal muscle actomyosin protein solutions to an 8 Hz, 25 microT extremely low frequency electromagnetic field, ATPase activity showed statistically significant time-dependent changes. Activity was inhibited versus control after 1, 2, and 4 hours, and increased after 3 and 5 hours; a similar pattern was observed with Mg2+/Ca2+ present and in their absence.

Outcomes measured

  • Mg2+/Ca2+-ATPase activity of actomyosin
  • K(+)-ATPase activity of actomyosin

Limitations

  • In vitro protein-solution experiment; findings may not generalize to intact organisms or humans
  • Sample size not reported in the abstract
  • Only one frequency (8 Hz) and one magnetic induction level (25 microT) described
  • Exposure duration limited to 5 hours; longer-term effects not assessed
View raw extracted JSON
{
    "study_type": "in_vitro",
    "exposure": {
        "band": "ELF",
        "source": "other",
        "frequency_mhz": 7.999999999999999637984894607090069484911509789526462554931640625e-6,
        "sar_wkg": null,
        "duration": "5 hours"
    },
    "population": "Rabbit skeletal muscle actomyosin protein solutions (in vitro)",
    "sample_size": null,
    "outcomes": [
        "Mg2+/Ca2+-ATPase activity of actomyosin",
        "K(+)-ATPase activity of actomyosin"
    ],
    "main_findings": "During 5-hour exposure of rabbit skeletal muscle actomyosin protein solutions to an 8 Hz, 25 microT extremely low frequency electromagnetic field, ATPase activity showed statistically significant time-dependent changes. Activity was inhibited versus control after 1, 2, and 4 hours, and increased after 3 and 5 hours; a similar pattern was observed with Mg2+/Ca2+ present and in their absence.",
    "effect_direction": "mixed",
    "limitations": [
        "In vitro protein-solution experiment; findings may not generalize to intact organisms or humans",
        "Sample size not reported in the abstract",
        "Only one frequency (8 Hz) and one magnetic induction level (25 microT) described",
        "Exposure duration limited to 5 hours; longer-term effects not assessed"
    ],
    "evidence_strength": "low",
    "confidence": 0.7800000000000000266453525910037569701671600341796875,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "extremely low frequency",
        "ELF EMF",
        "8 Hz",
        "25 microT",
        "actomyosin",
        "ATPase activity",
        "rabbit skeletal muscle",
        "Fiske-Subbarow method",
        "time dynamics",
        "enzyme activity"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.