Orientation of purple membrane in combined electric and magnetic fields.

PAPER pubmed FEBS letters 1995 Engineering / measurement Effect: benefit Evidence: Low

Abstract

The orientation of purple membrane in gels for photoelectric measurements is relatively poor, when they are prepared with the standard technique of applying a DC electric field and rapid polymerization. We have improved it by adding a high magnetic field (17.5 T) and increasing the viscosity of the membrane suspension. This process has resulted so far in a 3-fold increase of the photoelectric signals obtained. The magnetic susceptibility of purple membrane was determined.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
benefit
Population
—
Sample size
—
Exposure
combined electric and magnetic fields (DC electric field; high magnetic field)
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Standard preparation using a DC electric field and rapid polymerization produced relatively poor orientation of purple membrane in gels. Adding a high magnetic field (17.5 T) and increasing suspension viscosity improved orientation and resulted in a 3-fold increase in photoelectric signals; magnetic susceptibility of purple membrane was determined.

Outcomes measured

  • orientation of purple membrane in gels
  • photoelectric signal amplitude
  • magnetic susceptibility of purple membrane

Limitations

  • No sample size or quantitative statistical details provided in the abstract.
  • Exposure parameters for the DC electric field (strength, duration) are not described in the abstract.
  • Study is on purple membrane in gels (non-human, non-animal biological material), limiting generalizability to health outcomes.
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": null,
        "source": "combined electric and magnetic fields (DC electric field; high magnetic field)",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "orientation of purple membrane in gels",
        "photoelectric signal amplitude",
        "magnetic susceptibility of purple membrane"
    ],
    "main_findings": "Standard preparation using a DC electric field and rapid polymerization produced relatively poor orientation of purple membrane in gels. Adding a high magnetic field (17.5 T) and increasing suspension viscosity improved orientation and resulted in a 3-fold increase in photoelectric signals; magnetic susceptibility of purple membrane was determined.",
    "effect_direction": "benefit",
    "limitations": [
        "No sample size or quantitative statistical details provided in the abstract.",
        "Exposure parameters for the DC electric field (strength, duration) are not described in the abstract.",
        "Study is on purple membrane in gels (non-human, non-animal biological material), limiting generalizability to health outcomes."
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "purple membrane",
        "orientation",
        "DC electric field",
        "magnetic field",
        "17.5 T",
        "viscosity",
        "photoelectric measurements",
        "magnetic susceptibility"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.