Influence of discharge parameters on the resultant sputtered crater shapes for a radio frequency glow discharge atomic emission source.
Abstract
A parametric study has been conducted on a radio frequency glow discharge atomic emission spectrometry (rf-GD-AES) source to evaluate the sputtering characteristics and resultant crater shapes for both metallic and nonconducting samples. These studies include a determination of how the operating parameters, namely, power and pressure, influence the sputtered crater's depth, the degree of convexity and/or concavity, and the crater bottom roughness. The results imply that many similarities exist between the rf mode of powering and the well-characterized dc powered devices. Some differences are noted, namely, differing crater shapes at low operating pressures and a lesser dependence of crater flatness on the applied voltage, i.e., dc-bias voltage. A new method of quantifying the degree of concavity/convexity is introduced which involves comparison of the calculated (ideal) cross-sectional area to the resultant crater area as measured by a diamond stylus profilometer. The studies indicate that the rf-GD is well suited for depth-resolved analysis under correctly chosen operating conditions, which fortuitously correspond to those used for optimum bulk elemental analyses.
AI evidence extraction
Main findings
A parametric study of an rf glow discharge atomic emission spectrometry source found that operating parameters (power and pressure) influence crater depth, convexity/concavity, and bottom roughness for metallic and nonconducting samples. Similarities to dc-powered devices were reported, with differences including differing crater shapes at low pressures and a lesser dependence of crater flatness on applied (dc-bias) voltage. The authors introduce a method to quantify concavity/convexity by comparing an ideal calculated cross-sectional area to the measured crater area, and conclude the rf-GD is well suited for depth-resolved analysis under appropriately chosen conditions.
Outcomes measured
- Sputtered crater depth
- Crater convexity/concavity
- Crater bottom roughness
- Dependence of crater shape/flatness on operating parameters (power, pressure, dc-bias voltage)
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": "RF",
"source": "radio frequency glow discharge atomic emission spectrometry source",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"Sputtered crater depth",
"Crater convexity/concavity",
"Crater bottom roughness",
"Dependence of crater shape/flatness on operating parameters (power, pressure, dc-bias voltage)"
],
"main_findings": "A parametric study of an rf glow discharge atomic emission spectrometry source found that operating parameters (power and pressure) influence crater depth, convexity/concavity, and bottom roughness for metallic and nonconducting samples. Similarities to dc-powered devices were reported, with differences including differing crater shapes at low pressures and a lesser dependence of crater flatness on applied (dc-bias) voltage. The authors introduce a method to quantify concavity/convexity by comparing an ideal calculated cross-sectional area to the measured crater area, and conclude the rf-GD is well suited for depth-resolved analysis under appropriately chosen conditions.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"radio frequency",
"glow discharge",
"atomic emission spectrometry",
"sputtering",
"crater shape",
"power",
"pressure",
"dc-bias voltage",
"profilometer",
"depth-resolved analysis"
],
"suggested_hubs": []
}
AI can be wrong. Always verify against the paper.