Share
𝕏 Facebook LinkedIn

Influence of discharge parameters on the resultant sputtered crater shapes for a radio frequency glow discharge atomic emission source.

PAPER pubmed Analytical chemistry 1996 Engineering / measurement Effect: unclear Evidence: Insufficient

Abstract

A parametric study has been conducted on a radio frequency glow discharge atomic emission spectrometry (rf-GD-AES) source to evaluate the sputtering characteristics and resultant crater shapes for both metallic and nonconducting samples. These studies include a determination of how the operating parameters, namely, power and pressure, influence the sputtered crater's depth, the degree of convexity and/or concavity, and the crater bottom roughness. The results imply that many similarities exist between the rf mode of powering and the well-characterized dc powered devices. Some differences are noted, namely, differing crater shapes at low operating pressures and a lesser dependence of crater flatness on the applied voltage, i.e., dc-bias voltage. A new method of quantifying the degree of concavity/convexity is introduced which involves comparison of the calculated (ideal) cross-sectional area to the resultant crater area as measured by a diamond stylus profilometer. The studies indicate that the rf-GD is well suited for depth-resolved analysis under correctly chosen operating conditions, which fortuitously correspond to those used for optimum bulk elemental analyses.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
unclear
Population
—
Sample size
—
Exposure
RF radio frequency glow discharge atomic emission spectrometry source
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

A parametric study of an rf glow discharge atomic emission spectrometry source found that operating parameters (power and pressure) influence crater depth, convexity/concavity, and bottom roughness for metallic and nonconducting samples. Similarities to dc-powered devices were reported, with differences including differing crater shapes at low pressures and a lesser dependence of crater flatness on applied (dc-bias) voltage. The authors introduce a method to quantify concavity/convexity by comparing an ideal calculated cross-sectional area to the measured crater area, and conclude the rf-GD is well suited for depth-resolved analysis under appropriately chosen conditions.

Outcomes measured

  • Sputtered crater depth
  • Crater convexity/concavity
  • Crater bottom roughness
  • Dependence of crater shape/flatness on operating parameters (power, pressure, dc-bias voltage)
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": "RF",
        "source": "radio frequency glow discharge atomic emission spectrometry source",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Sputtered crater depth",
        "Crater convexity/concavity",
        "Crater bottom roughness",
        "Dependence of crater shape/flatness on operating parameters (power, pressure, dc-bias voltage)"
    ],
    "main_findings": "A parametric study of an rf glow discharge atomic emission spectrometry source found that operating parameters (power and pressure) influence crater depth, convexity/concavity, and bottom roughness for metallic and nonconducting samples. Similarities to dc-powered devices were reported, with differences including differing crater shapes at low pressures and a lesser dependence of crater flatness on applied (dc-bias) voltage. The authors introduce a method to quantify concavity/convexity by comparing an ideal calculated cross-sectional area to the measured crater area, and conclude the rf-GD is well suited for depth-resolved analysis under appropriately chosen conditions.",
    "effect_direction": "unclear",
    "limitations": [],
    "evidence_strength": "insufficient",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "radio frequency",
        "glow discharge",
        "atomic emission spectrometry",
        "sputtering",
        "crater shape",
        "power",
        "pressure",
        "dc-bias voltage",
        "profilometer",
        "depth-resolved analysis"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.