Share
𝕏 Facebook LinkedIn

Mechanical properties of resin composites with filler particles aligned by an electric field.

PAPER pubmed Dental materials : official publication of the Academy of Dental Materials 1998 Engineering / measurement Effect: benefit Evidence: Low

Abstract

OBJECTIVES: To explore possible enhancement of the mechanical properties of resin composites by aligning the filler particles. METHODS: The resin for the composites consisted of urethane dimethacrylate (UDMA) and 1,6-hexanediol dimethacrylate (HDDMA) mixed in the ratio of 90 to 10; the filler was silica-zirconia in two particle sizes, 1.7 microns (P50), which was mixed with the resin in the volume fractions of 29 and 48 vol%, and 0.7 micron (Z100), which was mixed with the resin in the volume fractions of 37 and 57 vol%. Particle alignment was obtained by applying a 60 Hz AC electric field across the composite before the resin was photopolymerized. The stress-strain behavior and the elastic modulus of the hardened composite were measured along the alignment axis in compression. RESULTS: The elastic moduli of the aligned composites increased by as much as 20%, and the maximum stress sustainable in compression before significant deformation occurred was elevated. An electric field strength of the order of 1 kV mm-1 was required to obtain sufficient alignment. SIGNIFICANCE: Besides conferring a structure to resin composites that is more like that of the natural tooth, particle alignment increased some of the mechanical properties and may have improved durability.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
benefit
Population
—
Sample size
—
Exposure
ELF other
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Silica-zirconia filler particles were aligned in resin composites using a 60 Hz AC electric field prior to photopolymerization. Aligned composites showed elastic modulus increases up to about 20% and higher maximum compressive stress before significant deformation; field strength on the order of 1 kV/mm was reported as required for sufficient alignment.

Outcomes measured

  • Elastic modulus
  • Compressive stress/maximum sustainable stress before significant deformation
  • Stress-strain behavior

Limitations

  • No sample size reported in abstract
  • No details provided on experimental replication/variability or statistical testing in abstract
  • Exposure duration and exact field parameters beyond frequency and approximate strength not reported in abstract
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": "ELF",
        "source": "other",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Elastic modulus",
        "Compressive stress/maximum sustainable stress before significant deformation",
        "Stress-strain behavior"
    ],
    "main_findings": "Silica-zirconia filler particles were aligned in resin composites using a 60 Hz AC electric field prior to photopolymerization. Aligned composites showed elastic modulus increases up to about 20% and higher maximum compressive stress before significant deformation; field strength on the order of 1 kV/mm was reported as required for sufficient alignment.",
    "effect_direction": "benefit",
    "limitations": [
        "No sample size reported in abstract",
        "No details provided on experimental replication/variability or statistical testing in abstract",
        "Exposure duration and exact field parameters beyond frequency and approximate strength not reported in abstract"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "resin composites",
        "dental materials",
        "filler particle alignment",
        "electric field",
        "60 Hz",
        "AC electric field",
        "elastic modulus",
        "compression"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments