[Improvement of the surface coil of weida low magnetic field imaging system].

PAPER pubmed Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation 1998 Engineering / measurement Effect: benefit Evidence: Insufficient

Abstract

By Replacing Litg wire with copper tube (phi 6 mm, thickness 0.7 mm), we increase the WEIDA low magnetic field imaging system surface coil's signal to noise ratio from 12 to 23, quality factor from 60 to 136, and reduce bandwidth from 50 kHz to 30 kHz.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
benefit
Population
—
Sample size
—
Exposure
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

Replacing Litz wire with a copper tube (6 mm diameter, 0.7 mm thickness) increased the surface coil signal-to-noise ratio from 12 to 23 and the quality factor from 60 to 136, while reducing bandwidth from 50 kHz to 30 kHz in the WEIDA low magnetic field imaging system.

Outcomes measured

  • signal-to-noise ratio
  • quality factor
  • bandwidth
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": null,
        "source": null,
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "signal-to-noise ratio",
        "quality factor",
        "bandwidth"
    ],
    "main_findings": "Replacing Litz wire with a copper tube (6 mm diameter, 0.7 mm thickness) increased the surface coil signal-to-noise ratio from 12 to 23 and the quality factor from 60 to 136, while reducing bandwidth from 50 kHz to 30 kHz in the WEIDA low magnetic field imaging system.",
    "effect_direction": "benefit",
    "limitations": [],
    "evidence_strength": "insufficient",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "surface coil",
        "low magnetic field imaging system",
        "coil design",
        "signal-to-noise ratio",
        "quality factor",
        "bandwidth",
        "copper tube",
        "Litz wire"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.