[Radiofrequency treatment of ethmoidal nerve with allergic rhinitis under nasal endoscopy].
Abstract
OBJECTIVE: To study the effect of radiofrequency treatment of ethmoidal nerve on allergic rhinitis. METHOD: Eighty-eight cases of allergic rhinitis were treated with ethmoidal nerve radiofrequency under nasal endoscopy. RESULT: It showed marked effectiveness in 73 cases (83.0%), immprovement in 11 cases (12.5%) and failed in 4 cases (4.5%) in one year follow-up. The overall effective rate was 95.5%. CONCLUSION: This result indicated that it is a choice for treating allergic rhinitis to apply ethmoidal nerve radiofrequency under nasal endoscopy.
AI evidence extraction
Main findings
Among 88 allergic rhinitis cases treated with ethmoidal nerve radiofrequency under nasal endoscopy, 73 (83.0%) had marked effectiveness, 11 (12.5%) improved, and 4 (4.5%) failed at 1-year follow-up; overall effective rate was 95.5%.
Outcomes measured
- Allergic rhinitis treatment effectiveness (marked effectiveness, improvement, failure) at 1-year follow-up
Limitations
- No control/comparator group described in abstract
- Radiofrequency exposure parameters (e.g., frequency, power, SAR) not reported
- Outcome definitions and measurement methods not described
- Blinding and randomization not described
View raw extracted JSON
{
"study_type": "other",
"exposure": {
"band": null,
"source": "medical radiofrequency treatment (ethmoidal nerve radiofrequency under nasal endoscopy)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": "treatment with 1-year follow-up"
},
"population": "Patients with allergic rhinitis",
"sample_size": 88,
"outcomes": [
"Allergic rhinitis treatment effectiveness (marked effectiveness, improvement, failure) at 1-year follow-up"
],
"main_findings": "Among 88 allergic rhinitis cases treated with ethmoidal nerve radiofrequency under nasal endoscopy, 73 (83.0%) had marked effectiveness, 11 (12.5%) improved, and 4 (4.5%) failed at 1-year follow-up; overall effective rate was 95.5%.",
"effect_direction": "benefit",
"limitations": [
"No control/comparator group described in abstract",
"Radiofrequency exposure parameters (e.g., frequency, power, SAR) not reported",
"Outcome definitions and measurement methods not described",
"Blinding and randomization not described"
],
"evidence_strength": "low",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"radiofrequency",
"ethmoidal nerve",
"nasal endoscopy",
"allergic rhinitis",
"treatment outcome"
],
"suggested_hubs": []
}
AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.