Share
𝕏 Facebook LinkedIn

Effects of 50 Hz sinusoidal electromagnetic fields on MCP-1 and RANTES generated from activated human macrophages.

PAPER pubmed International journal of immunopathology and pharmacology 2001 In vitro study Effect: mixed Evidence: Low

Abstract

Extremely low frequency electromagnetic fields (ELF-EMF) induce cellular changes and modulate signal transduction pathways, and may be beneficial in the treatment of inflammatory diseases. In this paper we studied two inflammatory chemokines, MCP-1 and RANTES produced by human cultured isolated monocytes from peripheral blood, with or without PHA and in the absence or presence of 50 Hz magnetic field of 1.0 mT for 24 h. The production of MCP-1 and RANTES was determined by ELISA method. Here, we found that ELF-EMF strongly inhibited the production of these chemokines stimulated by PHA, while the control was not affected. Since MCP-1 and RANTES exert chemoattraction for several populations inflammatory leukocytes, the inhibitory effect of these chemokines could be one of the mechanisms by which ELF-EMF is therapeutic in inflammatory diseases.

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
mixed
Population
Human cultured isolated monocytes from peripheral blood (activated with PHA to generate macrophage/monocyte responses)
Sample size
—
Exposure
ELF · 0.05 MHz · 24 h
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

In human cultured isolated monocytes, exposure to a 50 Hz magnetic field (1.0 mT) for 24 h strongly inhibited PHA-stimulated production of MCP-1 and RANTES, while unstimulated control production was not affected.

Outcomes measured

  • MCP-1 production (ELISA)
  • RANTES production (ELISA)

Limitations

  • In vitro study; findings may not translate to in vivo or clinical outcomes
  • Sample size not reported in the abstract
  • Only one field strength (1.0 mT) and one exposure duration (24 h) described
  • Limited outcomes (two chemokines) reported

Suggested hubs

  • elf-emf (0.9)
    Study examines 50 Hz extremely low frequency magnetic field exposure.
  • inflammation-immunology (0.6)
    Measures inflammatory chemokines MCP-1 and RANTES in human immune cells.
View raw extracted JSON
{
    "study_type": "in_vitro",
    "exposure": {
        "band": "ELF",
        "source": null,
        "frequency_mhz": 0.05000000000000000277555756156289135105907917022705078125,
        "sar_wkg": null,
        "duration": "24 h"
    },
    "population": "Human cultured isolated monocytes from peripheral blood (activated with PHA to generate macrophage/monocyte responses)",
    "sample_size": null,
    "outcomes": [
        "MCP-1 production (ELISA)",
        "RANTES production (ELISA)"
    ],
    "main_findings": "In human cultured isolated monocytes, exposure to a 50 Hz magnetic field (1.0 mT) for 24 h strongly inhibited PHA-stimulated production of MCP-1 and RANTES, while unstimulated control production was not affected.",
    "effect_direction": "mixed",
    "limitations": [
        "In vitro study; findings may not translate to in vivo or clinical outcomes",
        "Sample size not reported in the abstract",
        "Only one field strength (1.0 mT) and one exposure duration (24 h) described",
        "Limited outcomes (two chemokines) reported"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "ELF-EMF",
        "50 Hz",
        "magnetic field",
        "1.0 mT",
        "monocytes",
        "macrophages",
        "PHA",
        "MCP-1",
        "RANTES",
        "chemokines",
        "inflammation",
        "ELISA"
    ],
    "suggested_hubs": [
        {
            "slug": "elf-emf",
            "weight": 0.90000000000000002220446049250313080847263336181640625,
            "reason": "Study examines 50 Hz extremely low frequency magnetic field exposure."
        },
        {
            "slug": "inflammation-immunology",
            "weight": 0.59999999999999997779553950749686919152736663818359375,
            "reason": "Measures inflammatory chemokines MCP-1 and RANTES in human immune cells."
        }
    ]
}

AI can be wrong. Always verify against the paper.