Monitoring the ultrafast electric field change at a mid-infrared plasma Bragg mirror.
Abstract
The electric field change of a femtosecond mid-infrared (MIR) pulse reflected by a new type of Bragg mirror is directly measured by time-resolved cross-correlation spectroscopy. The refractive-index contrast of the plasma Bragg mirror is achieved by use of different doping levels of only one type of semiconductor material (n(+) -doped GaAs and undoped GaAs). The direct measurement of the time dependence of the electric field of a reflected MIR pulse permits the observation of a noninstantaneous response of a Bragg mirror compared with a metallic surface, which is due to the penetration of the pulse into the multilayer structure.
AI evidence extraction
Main findings
The time dependence of the electric field of a reflected femtosecond mid-infrared pulse from a plasma Bragg mirror was directly measured using time-resolved cross-correlation spectroscopy. The measurements showed a noninstantaneous response of the Bragg mirror compared with a metallic surface, attributed to pulse penetration into the multilayer structure.
Outcomes measured
- Time dependence of reflected mid-infrared pulse electric field
- Noninstantaneous response of plasma Bragg mirror vs metallic surface
View raw extracted JSON
{
"study_type": "engineering",
"exposure": {
"band": null,
"source": null,
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"Time dependence of reflected mid-infrared pulse electric field",
"Noninstantaneous response of plasma Bragg mirror vs metallic surface"
],
"main_findings": "The time dependence of the electric field of a reflected femtosecond mid-infrared pulse from a plasma Bragg mirror was directly measured using time-resolved cross-correlation spectroscopy. The measurements showed a noninstantaneous response of the Bragg mirror compared with a metallic surface, attributed to pulse penetration into the multilayer structure.",
"effect_direction": "unclear",
"limitations": [],
"evidence_strength": "insufficient",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"mid-infrared",
"femtosecond pulse",
"electric field measurement",
"Bragg mirror",
"plasma Bragg mirror",
"GaAs",
"time-resolved cross-correlation spectroscopy",
"multilayer structure"
],
"suggested_hubs": []
}
AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.