[Elective resection of the spleen--overview of resection technics and description of a new technic based on radiofrequency coagulation and dessication].

PAPER pubmed Acta chirurgica Iugoslavica 2002 Case report Effect: unclear Evidence: Very low

Abstract

The authors present a short overview of the development of elective splenic resections. Past and present indications are presented. Contemporary hemostatic technique for elective splenic resection are discussed. An original new technique for transsegmental partial splenic resection using RF generator Radionic Cool Tip(without any aditional hemostatic procedures is presented. This technique is inovative and when use properly it is a practically zero blood loos technique. A patient with transsegmental splenic resection using RF generator is presented. Further clinical application of the technique is necessary.

AI evidence extraction

At a glance
Study type
Case report
Effect direction
unclear
Population
—
Sample size
1
Exposure
radiofrequency surgical generator (Radionic Cool Tip)
Evidence strength
Very low
Confidence: 74% · Peer-reviewed: yes

Main findings

The paper describes an original technique for transsegmental partial splenic resection using an RF generator (Radionic Cool Tip) without additional hemostatic procedures. The authors state that when used properly it is a practically zero blood loss technique, and they present one patient treated with this method; they note further clinical application is necessary.

Outcomes measured

  • surgical technique for partial splenic resection
  • hemostasis/blood loss during splenic resection

Limitations

  • Case report (single patient)
  • No quantitative exposure parameters (e.g., frequency, power) reported in abstract
  • No comparative/control group described
  • Further clinical application stated as necessary
View raw extracted JSON
{
    "study_type": "case_report",
    "exposure": {
        "band": null,
        "source": "radiofrequency surgical generator (Radionic Cool Tip)",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": 1,
    "outcomes": [
        "surgical technique for partial splenic resection",
        "hemostasis/blood loss during splenic resection"
    ],
    "main_findings": "The paper describes an original technique for transsegmental partial splenic resection using an RF generator (Radionic Cool Tip) without additional hemostatic procedures. The authors state that when used properly it is a practically zero blood loss technique, and they present one patient treated with this method; they note further clinical application is necessary.",
    "effect_direction": "unclear",
    "limitations": [
        "Case report (single patient)",
        "No quantitative exposure parameters (e.g., frequency, power) reported in abstract",
        "No comparative/control group described",
        "Further clinical application stated as necessary"
    ],
    "evidence_strength": "very_low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "splenic resection",
        "partial splenectomy",
        "radiofrequency coagulation",
        "radiofrequency dessication",
        "hemostasis",
        "surgical technique"
    ],