[Experimental study on the disinfection of wastewater by swept pulsed electromagnetic field].

PAPER pubmed Huan jing ke xue= Huanjing kexue 2003 Engineering / measurement Effect: benefit Evidence: Low

Abstract

In this paper, an applicable swept pulsed equipment was developed to treat the domestic wastewater and the effect of swept pulsed electromagnetic field on disinfection was studied. It was found that the effect was obvious and the disinfection performance of electromagnetic field was increased with the increasing of the pH, the temperature, the treatment time and the bactericidal concentration. The experimental results showed that the amounts of total bacterium and coliform per milliliter were decreased from 7.2 x 10(6) to 2.2 x 10(4) and from 9.2 x 10(5) to 3.5 x 10(4) respectively after the treatment period of 4 h when the temperature was 25 degrees C and pH 9.0. Corresponding, the removal efficiency of total bacterium were 99.7% and 96.2%.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
benefit
Population
—
Sample size
—
Exposure
swept pulsed electromagnetic field equipment (wastewater treatment) · 4 h
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

A swept pulsed electromagnetic field treatment was reported to reduce bacterial loads in domestic wastewater. After 4 h at 25°C and pH 9.0, total bacteria decreased from 7.2×10^6 to 2.2×10^4 per mL and coliforms from 9.2×10^5 to 3.5×10^4 per mL; reported removal efficiencies were 99.7% and 96.2%, respectively. Disinfection performance increased with higher pH, temperature, treatment time, and bactericidal concentration.

Outcomes measured

  • wastewater disinfection performance
  • total bacterium count per mL
  • coliform count per mL
  • removal efficiency of total bacterium and coliform

Limitations

  • No electromagnetic field parameters (e.g., frequency, field strength, pulse characteristics) reported in the abstract
  • No sample size or replication details provided
  • No control/comparator described in the abstract
  • Outcome reporting limited to bacterial counts under selected conditions
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": null,
        "source": "swept pulsed electromagnetic field equipment (wastewater treatment)",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "4 h"
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "wastewater disinfection performance",
        "total bacterium count per mL",
        "coliform count per mL",
        "removal efficiency of total bacterium and coliform"
    ],
    "main_findings": "A swept pulsed electromagnetic field treatment was reported to reduce bacterial loads in domestic wastewater. After 4 h at 25°C and pH 9.0, total bacteria decreased from 7.2×10^6 to 2.2×10^4 per mL and coliforms from 9.2×10^5 to 3.5×10^4 per mL; reported removal efficiencies were 99.7% and 96.2%, respectively. Disinfection performance increased with higher pH, temperature, treatment time, and bactericidal concentration.",
    "effect_direction": "benefit",
    "limitations": [
        "No electromagnetic field parameters (e.g., frequency, field strength, pulse characteristics) reported in the abstract",
        "No sample size or replication details provided",
        "No control/comparator described in the abstract",
        "Outcome reporting limited to bacterial counts under selected conditions"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "swept pulsed electromagnetic field",
        "wastewater",
        "disinfection",
        "total bacteria",
        "coliform",
        "pH",
        "temperature",
        "treatment time"
    ],
    "suggested_hubs": []
}