A radiofrequency modified maze and valve procedure through a port-access approach.
Abstract
BACKGROUND: The aim of the study was to assess the feasibility and effectiveness of the irrigated radiofrequency modified maze procedure through a port-access approach during mitral valve surgery. METHODS: Forty-three patients with atrial fibrillation (AF) and mitral valve disease underwent a combined procedure through a port-access approach. The indication was a history of continuous AF for more than 6 months in patients eligible for minimally invasive mitral valve surgery. RESULTS: The incidence of early mortality was 1 patient (2.3%), and that of freedom from AF was 100% at the end of the operation (70% of patients with normal sinus rhythm, 30% with a pacemaker). One patient (2.3%) required permanent pacemaker implantation after surgery. One patient (2.3%) required reoperation for bleeding. There were no reoperations for failed valve repairs. The incidences of freedom from AF were 87% and 92% at 6 and 12 months, respectively. At 12 months, functional capacity had improved significantly (P < .05). There were no procedure-related complications. No thromboembolic events were detected during follow-up. CONCLUSION: The port-access approach provided a good access for both valve surgery and the radiofrequency maze procedure. The combination of direct and videoscopic vision allowed an adequate view and led to a safe and efficient combined procedure. Short- and intermediate-term follow-up results were favorable.
AI evidence extraction
Main findings
In 43 patients, early mortality was 2.3%. Freedom from AF was reported as 100% at the end of the operation and 87% and 92% at 6 and 12 months, respectively; functional capacity improved significantly at 12 months (P<.05). One patient required permanent pacemaker implantation and one required reoperation for bleeding; no procedure-related complications or thromboembolic events were detected during follow-up.
Outcomes measured
- Feasibility of port-access approach for irrigated radiofrequency modified maze during mitral valve surgery
- Early mortality
- Freedom from atrial fibrillation (end of operation; 6 and 12 months)
- Need for permanent pacemaker implantation
- Reoperation for bleeding
- Reoperation for failed valve repair
- Functional capacity at 12 months
- Procedure-related complications
- Thromboembolic events during follow-up
Limitations
- No control/comparator group described in the abstract
- Follow-up limited to short/intermediate term (reported to 12 months)
- Frequency/dose parameters of radiofrequency energy not reported in the abstract
View raw extracted JSON
{
"study_type": "other",
"exposure": {
"band": null,
"source": "medical radiofrequency ablation (surgical maze procedure)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Patients with atrial fibrillation and mitral valve disease undergoing minimally invasive mitral valve surgery",
"sample_size": 43,
"outcomes": [
"Feasibility of port-access approach for irrigated radiofrequency modified maze during mitral valve surgery",
"Early mortality",
"Freedom from atrial fibrillation (end of operation; 6 and 12 months)",
"Need for permanent pacemaker implantation",
"Reoperation for bleeding",
"Reoperation for failed valve repair",
"Functional capacity at 12 months",
"Procedure-related complications",
"Thromboembolic events during follow-up"
],
"main_findings": "In 43 patients, early mortality was 2.3%. Freedom from AF was reported as 100% at the end of the operation and 87% and 92% at 6 and 12 months, respectively; functional capacity improved significantly at 12 months (P<.05). One patient required permanent pacemaker implantation and one required reoperation for bleeding; no procedure-related complications or thromboembolic events were detected during follow-up.",
"effect_direction": "benefit",
"limitations": [
"No control/comparator group described in the abstract",
"Follow-up limited to short/intermediate term (reported to 12 months)",
"Frequency/dose parameters of radiofrequency energy not reported in the abstract"
],
"evidence_strength": "low",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"radiofrequency",
"modified maze procedure",
"port-access",
"minimally invasive",
"mitral valve surgery",
"atrial fibrillation",
"pacemaker",
"follow-up"
],
"suggested_hubs": []
}
AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.