[Effect of extremely low frequency magnetic fields on intracellular free calcium in HepG2 cells].
Abstract
OBJECTIVE: To study the effect of extremely low frequency magnetic fields on intracellular calcium concentration ([Ca(2+)]i). METHODS: Fura-2 loaded HepG2 cells were exposed to 1.55 mT (average value), 16 Hz pulsed magnetic fields for 60 min and to 300 mT, 2 Hz rotating magnetic fields for 5 min, and then [Ca(2+)]i was measured by fluorescence spectrophotometer. [Ca(2+)]i of HepG2 cells was also measured when they were exposed to 0.9 mT [root mean square (rms)], 16 Hz sinusoidal magnetic fields in real time. RESULTS: The R values (F(340) nm/F(380) nm) of the control and the exposed group were 2.4519 +/- 0.2378 and 2.5266 +/- 0.2915 respectively after HepG2 cells were exposed to 1.55 mT, 16 Hz magnetic fields, 1.365 0 +/- 0.0626 and 1.3602 +/- 0.0771 respectively to 300 mT, 2 Hz rotating magnetic fields. The ratios of the trendline slope [r((501 - 1,000)) / r((0 - 500))] from the data of R values were 1.1213 +/- 0.4559 and 1.0727 +/- 0.1971 respectively (P > 0.05), and the ratios of the intercept [b((501 - 1,000)) / b((0 - 500))] from the trendline were 0.9912 +/- 0.0098 and 0.9979 +/- 0.0060 (P > 0.05) when HepG2 cells were exposed to the 0.9 mT, 16 Hz sinusoidal magnetic fields. CONCLUSION: The effect of extremely low frequency magnetic fields on [Ca(2+)]i of HepG2 cells under the experimental condition has not been found.
AI evidence extraction
Main findings
No statistically significant differences in Fura-2 fluorescence ratio measures were observed between control and exposed HepG2 cells under 1.55 mT 16 Hz pulsed exposure, 300 mT 2 Hz rotating exposure, or during real-time 0.9 mT 16 Hz sinusoidal exposure (P > 0.05). The authors conclude no effect on intracellular free calcium under the experimental conditions.
Outcomes measured
- intracellular free calcium concentration ([Ca2+]i)
- Fura-2 fluorescence ratio R (F340/F380)
Limitations
- Sample size not reported in abstract
- Only one cell line (HepG2) studied
- Limited exposure conditions/durations reported (specific field types and short durations)
Suggested hubs
-
occupational-exposure
(0.35) Published in an industrial hygiene/occupational diseases journal and studies ELF magnetic field exposure effects (though in vitro).
View raw extracted JSON
{
"study_type": "in_vitro",
"exposure": {
"band": "ELF",
"source": null,
"frequency_mhz": null,
"sar_wkg": null,
"duration": "60 min (1.55 mT, 16 Hz pulsed); 5 min (300 mT, 2 Hz rotating); real-time measurement during 0.9 mT, 16 Hz sinusoidal exposure"
},
"population": "HepG2 cells",
"sample_size": null,
"outcomes": [
"intracellular free calcium concentration ([Ca2+]i)",
"Fura-2 fluorescence ratio R (F340/F380)"
],
"main_findings": "No statistically significant differences in Fura-2 fluorescence ratio measures were observed between control and exposed HepG2 cells under 1.55 mT 16 Hz pulsed exposure, 300 mT 2 Hz rotating exposure, or during real-time 0.9 mT 16 Hz sinusoidal exposure (P > 0.05). The authors conclude no effect on intracellular free calcium under the experimental conditions.",
"effect_direction": "no_effect",
"limitations": [
"Sample size not reported in abstract",
"Only one cell line (HepG2) studied",
"Limited exposure conditions/durations reported (specific field types and short durations)"
],
"evidence_strength": "low",
"confidence": 0.7800000000000000266453525910037569701671600341796875,
"peer_reviewed_likely": "yes",
"keywords": [
"extremely low frequency",
"magnetic fields",
"ELF",
"HepG2",
"intracellular calcium",
"Fura-2",
"fluorescence spectrophotometer",
"pulsed magnetic field",
"rotating magnetic field",
"sinusoidal magnetic field"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.34999999999999997779553950749686919152736663818359375,
"reason": "Published in an industrial hygiene/occupational diseases journal and studies ELF magnetic field exposure effects (though in vitro)."
}
]
}
AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.