Share
𝕏 Facebook LinkedIn

Excitation properties of peripheral nerves stimulated by an induced transverse electric field during magnetic stimulation.

PAPER pubmed Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference 2005 Engineering / measurement Effect: unclear Evidence: Insufficient

Abstract

Interest in magnetic stimulation (MS) of peripheral nerves has grown rapidly, but difficulties in determining excitation sites and computing the stimulation efficiency have prevented magnetic stimulation from becoming a routing clinical tool. The classical cable function has demonstrated that the activating function of nerves is the first spatial derivative of the electric field component parallel to the nerves. Therefore, excellent analyses have been presented in the literatures which predict the excitation properties, for peripheral nerves stimulated by the induced electric field component parallel to the nerves during MS. There is not, however, an adequate analysis for nerves excitation which considers the induced field component perpendicular to the fibers. Based on the improved cable function, which introduces a transverse field component, we have analyzed the excitation sites and the stimulation efficiencies during MS using round coils and 8-shaped coils, respectively. That is helpful to the further development of the functional magnetic nerve stimulation technique and to the clinical application of MS.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
unclear
Population
—
Sample size
—
Exposure
magnetic stimulation (MS) using round coils and 8-shaped coils
Evidence strength
Insufficient
Confidence: 66% · Peer-reviewed: unknown

Main findings

Using an improved cable function that includes a transverse (perpendicular-to-fiber) induced electric field component, the authors analyzed excitation sites and stimulation efficiencies for peripheral nerves during magnetic stimulation with round and figure-8 coils. The work is presented as providing analysis not previously adequate for transverse field components and as helpful for development and clinical application of functional magnetic nerve stimulation.

Outcomes measured

  • Peripheral nerve excitation properties (excitation sites)
  • Stimulation efficiency during magnetic stimulation
  • Role of induced transverse (perpendicular) electric field component in nerve activation

Limitations

  • Appears to be an analytical/modeling study; no experimental validation or biological/clinical outcomes are described in the abstract.
  • No quantitative results, exposure parameters, or comparison metrics are provided in the abstract.

Suggested hubs

  • occupational-exposure (0.1)
    Magnetic stimulation is a medical/engineering exposure context; no occupational setting is stated, so relevance is weak.
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": null,
        "source": "magnetic stimulation (MS) using round coils and 8-shaped coils",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Peripheral nerve excitation properties (excitation sites)",
        "Stimulation efficiency during magnetic stimulation",
        "Role of induced transverse (perpendicular) electric field component in nerve activation"
    ],
    "main_findings": "Using an improved cable function that includes a transverse (perpendicular-to-fiber) induced electric field component, the authors analyzed excitation sites and stimulation efficiencies for peripheral nerves during magnetic stimulation with round and figure-8 coils. The work is presented as providing analysis not previously adequate for transverse field components and as helpful for development and clinical application of functional magnetic nerve stimulation.",
    "effect_direction": "unclear",
    "limitations": [
        "Appears to be an analytical/modeling study; no experimental validation or biological/clinical outcomes are described in the abstract.",
        "No quantitative results, exposure parameters, or comparison metrics are provided in the abstract."
    ],
    "evidence_strength": "insufficient",
    "confidence": 0.66000000000000003108624468950438313186168670654296875,
    "peer_reviewed_likely": "unknown",
    "keywords": [
        "magnetic stimulation",
        "peripheral nerves",
        "induced electric field",
        "transverse electric field",
        "cable function",
        "round coil",
        "figure-8 coil",
        "stimulation efficiency",
        "excitation site"
    ],
    "suggested_hubs": [
        {
            "slug": "occupational-exposure",
            "weight": 0.1000000000000000055511151231257827021181583404541015625,
            "reason": "Magnetic stimulation is a medical/engineering exposure context; no occupational setting is stated, so relevance is weak."
        }
    ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.