Share
𝕏 Facebook LinkedIn

Effects of monopolar radiofrequency heating on intradiscal pressure in sheep.

PAPER pubmed The spine journal : official journal of the North American Spine Society 2007 Animal study Effect: benefit Evidence: Low

Abstract

BACKGROUND CONTEXT: No previous study has assessed the effect of monopolar radiofrequency (RF) heating on intradiscal pressure. PURPOSE: To determine the decrease in lumbar intradiscal pressure after monopolar RF heating. STUDY DESIGN/SETTING: Intradiscal pressure was measured in sheep lumbar discs treated with monopolar RF heating. METHODS: Two monopolar RF heat treatments at 90 degrees C were applied for 2 minutes each to lumbar intervertebral discs of sheep. Intradiscal pressure was measured in live sheep at 0, 7, 14, 21, and 28 days posttreatment. Pressure measurements were taken with a microtip pressure transducer. Electrodes were inserted but not activated in separate discs as a sham control. In vitro sheep spine of different age groups, loading conditions, and electrode orientations were similarly heat treated and intradiscal pressures were measured. RESULTS: Intradiscal pressure was significantly reduced 1 week after monopolar RF heating and remained stable through the 4-week observation period. The RF electrode orientation, the age, and the type of disc loading have significant effects on the amount of initial intradiscal pressure reduction. CONCLUSIONS: Monopolar RF heating can reduce intradiscal pressure in the lumbar spine of sheep.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
benefit
Population
Sheep (lumbar intervertebral discs; in vivo and in vitro sheep spine)
Sample size
—
Exposure
RF medical/therapeutic radiofrequency heating (monopolar RF) · Two treatments at 90°C for 2 minutes each
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

In live sheep, intradiscal pressure was significantly reduced 1 week after monopolar RF heating and remained stable through 4 weeks. In vitro experiments indicated that electrode orientation, age group, and disc loading type significantly affected the magnitude of the initial pressure reduction.

Outcomes measured

  • Lumbar intradiscal pressure (measured at 0, 7, 14, 21, and 28 days posttreatment)

Limitations

  • Sample size not reported in abstract
  • RF exposure parameters (e.g., frequency, power, SAR) not reported
  • Animal model (sheep) and in vitro components may limit generalizability to humans
  • Follow-up limited to 4 weeks in vivo
View raw extracted JSON
{
    "study_type": "animal",
    "exposure": {
        "band": "RF",
        "source": "medical/therapeutic radiofrequency heating (monopolar RF)",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": "Two treatments at 90°C for 2 minutes each"
    },
    "population": "Sheep (lumbar intervertebral discs; in vivo and in vitro sheep spine)",
    "sample_size": null,
    "outcomes": [
        "Lumbar intradiscal pressure (measured at 0, 7, 14, 21, and 28 days posttreatment)"
    ],
    "main_findings": "In live sheep, intradiscal pressure was significantly reduced 1 week after monopolar RF heating and remained stable through 4 weeks. In vitro experiments indicated that electrode orientation, age group, and disc loading type significantly affected the magnitude of the initial pressure reduction.",
    "effect_direction": "benefit",
    "limitations": [
        "Sample size not reported in abstract",
        "RF exposure parameters (e.g., frequency, power, SAR) not reported",
        "Animal model (sheep) and in vitro components may limit generalizability to humans",
        "Follow-up limited to 4 weeks in vivo"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "radiofrequency heating",
        "monopolar RF",
        "intradiscal pressure",
        "lumbar disc",
        "sheep",
        "sham control",
        "in vivo",
        "in vitro"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.