Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths.
Abstract
In this study, a circulation system was used to measure T(1) values of bovine blood under physiological conditions at field strengths of 4.7, 7 and 9.4 T. Results show that T(1) increases linearly with magnetic field B(0) and can be described with the equation T(1)=129 ms/T B(0)+1167 ms for magnetic field strengths between 1.5 and 9.4 T.
AI evidence extraction
At a glance
Study type
Other
Effect direction
unclear
Population
Bovine blood (circulating system)
Sample size
—
Exposure
MRI (static magnetic field B0)
Evidence strength
Insufficient
Confidence: 74%
· Peer-reviewed: yes
Main findings
Using a circulation system under physiological conditions, bovine blood T1 increased linearly with magnetic field strength (B0) across 4.7, 7, and 9.4 T. The relationship was described as T1 = 129 ms/T * B0 + 1167 ms for magnetic field strengths between 1.5 and 9.4 T.
Outcomes measured
- Blood longitudinal relaxation time (T1)
Limitations
- Sample size not reported in abstract
- Study uses bovine blood in a circulation system; generalizability to humans not stated
- No health outcomes assessed; outcome is a measurement parameter (T1)
View raw extracted JSON
{
"study_type": "other",
"exposure": {
"band": null,
"source": "MRI (static magnetic field B0)",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Bovine blood (circulating system)",
"sample_size": null,
"outcomes": [
"Blood longitudinal relaxation time (T1)"
],
"main_findings": "Using a circulation system under physiological conditions, bovine blood T1 increased linearly with magnetic field strength (B0) across 4.7, 7, and 9.4 T. The relationship was described as T1 = 129 ms/T * B0 + 1167 ms for magnetic field strengths between 1.5 and 9.4 T.",
"effect_direction": "unclear",
"limitations": [
"Sample size not reported in abstract",
"Study uses bovine blood in a circulation system; generalizability to humans not stated",
"No health outcomes assessed; outcome is a measurement parameter (T1)"
],
"evidence_strength": "insufficient",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"MRI",
"static magnetic field",
"B0",
"T1 relaxation time",
"blood",
"high field strength",
"4.7 T",
"7 T",
"9.4 T"
],
"suggested_hubs": []
}
AI can be wrong. Always verify against the paper.
AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect.
This content is for informational purposes only and is not medical advice.
Comments
Log in to comment.
No comments yet.