Share
𝕏 Facebook LinkedIn

A mm-sized wirelessly powered and remotely controlled locomotive implant.

PAPER pubmed IEEE transactions on biomedical circuits and systems 2012 Engineering / measurement Effect: unclear Evidence: Insufficient

Abstract

A wirelessly powered and controlled implantable device capable of locomotion in a fluid medium is presented. Two scalable low-power propulsion methods are described that achieve roughly an order of magnitude better performance than existing methods in terms of thrust conversion efficiency. The wireless prototype occupies 0.6 mm × 1 mm in 65 nm CMOS with an external 2 mm × 2 mm receive antenna. The IC consists of a matching network, a rectifier, a bandgap reference, a regulator, a demodulator, a digital controller, and high-current drivers that interface directly with the propulsion system. It receives 500 μW from a 2 W 1.86 GHz power signal at a distance of 5 cm. Asynchronous pulse-width modulation on the carrier allows for data rates from 2.5-25 Mbps with energy efficiency of 0.5 pJ/b at 10 Mbps. The received data configures the propulsion system drivers, which are capable of driving up to 2 mA at 0.2 V and can achieve speed of 0.53 cm/sec in a 0.06 T magnetic field.

AI evidence extraction

At a glance
Study type
Engineering / measurement
Effect direction
unclear
Population
—
Sample size
—
Exposure
RF wireless power signal (implantable device) · 1860 MHz
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

A mm-scale implantable locomotive device was wirelessly powered and controlled. The prototype received 500 µW from a 2 W, 1.86 GHz power signal at 5 cm distance and supported 2.5–25 Mbps data rates via asynchronous PWM on the carrier; the propulsion drivers enabled locomotion up to 0.53 cm/s in a 0.06 T magnetic field.

Outcomes measured

  • Wireless power transfer performance (received power at distance)
  • Implant device locomotion/propulsion performance (speed, thrust conversion efficiency)
  • Wireless data communication performance (data rate, energy efficiency)

Limitations

  • No biological/health outcomes are reported in the abstract.
  • No exposure metrics such as SAR or tissue heating are reported.
  • Study context appears to be device engineering; population/sample details are not provided.
View raw extracted JSON
{
    "study_type": "engineering",
    "exposure": {
        "band": "RF",
        "source": "wireless power signal (implantable device)",
        "frequency_mhz": 1860,
        "sar_wkg": null,
        "duration": null
    },
    "population": null,
    "sample_size": null,
    "outcomes": [
        "Wireless power transfer performance (received power at distance)",
        "Implant device locomotion/propulsion performance (speed, thrust conversion efficiency)",
        "Wireless data communication performance (data rate, energy efficiency)"
    ],
    "main_findings": "A mm-scale implantable locomotive device was wirelessly powered and controlled. The prototype received 500 µW from a 2 W, 1.86 GHz power signal at 5 cm distance and supported 2.5–25 Mbps data rates via asynchronous PWM on the carrier; the propulsion drivers enabled locomotion up to 0.53 cm/s in a 0.06 T magnetic field.",
    "effect_direction": "unclear",
    "limitations": [
        "No biological/health outcomes are reported in the abstract.",
        "No exposure metrics such as SAR or tissue heating are reported.",
        "Study context appears to be device engineering; population/sample details are not provided."
    ],
    "evidence_strength": "insufficient",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "wireless power transfer",
        "implantable device",
        "locomotion",
        "CMOS",
        "1.86 GHz",
        "RF power signal",
        "asynchronous PWM",
        "data rate",
        "energy efficiency",
        "magnetic field"
    ],
    "suggested_hubs": []
}