Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging.
Abstract
PURPOSE: To retrospectively evaluate the conspicuity of liver lesions in a fluoroscopic spoiled gradient echo (GRE) and a balanced steady-state free precession (SSFP) magnetic resonance imaging (MRI) sequence. MATERIALS AND METHODS: In all, 103 patients with hepatocellular carcinomas (HCC) (41) or liver metastases (67) were treated using MR-guided radiofrequency ablation in a wide-bore 1.5 T scanner. A multislice real-time spoiled GRE sequence allowing for a T1 weighting (T1W) and a balanced SSFP sequence allowing for a T2/T1W contrast were used for MR guidance. The contrast-to-noise-ratio (CNR) of the lesions was calculated and lesion conspicuity was assessed retrospectively (easily detectable / difficult to detect / not detectable). RESULTS: HCC was easily detectable in 33/52% (GRE/SSFP), difficult to detect in 30/18%, and not detectable in 37/30% of the cases. Mean CNR varied widely (9.1 for GRE vs. 16.4 for SSFP). Liver metastases were easily detectable in 58/41% (GRE/SSFP), difficult to detect in 14/21%, and not detectable in 28/38% of the cases. Mean CNR for liver metastases was 11.5 (GRE) vs. 12.7 (SSFP). Twenty percent of all lesions could not be detected with either of the MR fluoroscopy sequences. CONCLUSION: MR fluoroscopy using GRE and SSFP contrast enabled real-time detectability of 80% of the liver lesions.
AI evidence extraction
Main findings
In 103 patients treated with MR-guided radiofrequency ablation, lesion detectability differed by sequence (spoiled GRE vs balanced SSFP) and lesion type. Overall, 20% of lesions could not be detected with either MR fluoroscopy sequence, implying 80% real-time detectability across sequences.
Outcomes measured
- Liver lesion conspicuity (easily detectable / difficult to detect / not detectable)
- Contrast-to-noise ratio (CNR)
Limitations
- Retrospective evaluation
View raw extracted JSON
{
"study_type": "other",
"exposure": {
"band": null,
"source": null,
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "Patients with hepatocellular carcinoma (HCC) or liver metastases undergoing MR-guided radiofrequency ablation in a 1.5 T MRI scanner",
"sample_size": 103,
"outcomes": [
"Liver lesion conspicuity (easily detectable / difficult to detect / not detectable)",
"Contrast-to-noise ratio (CNR)"
],
"main_findings": "In 103 patients treated with MR-guided radiofrequency ablation, lesion detectability differed by sequence (spoiled GRE vs balanced SSFP) and lesion type. Overall, 20% of lesions could not be detected with either MR fluoroscopy sequence, implying 80% real-time detectability across sequences.",
"effect_direction": "unclear",
"limitations": [
"Retrospective evaluation"
],
"evidence_strength": "low",
"confidence": 0.7399999999999999911182158029987476766109466552734375,
"peer_reviewed_likely": "yes",
"keywords": [
"MRI",
"MR fluoroscopy",
"spoiled gradient echo",
"balanced SSFP",
"liver lesions",
"hepatocellular carcinoma",
"liver metastases",
"MR-guided radiofrequency ablation",
"contrast-to-noise ratio",
"lesion conspicuity"
],
"suggested_hubs": []
}
AI can be wrong. Always verify against the paper.