Share
𝕏 Facebook LinkedIn

Visualizing radiofrequency lesions using delayed-enhancement magnetic resonance imaging in patients with atrial fibrillation: A modification of the method used by the University of Utah group.

PAPER pubmed Journal of arrhythmia 2015 Other Effect: unclear Evidence: Low

Abstract

BACKGROUND: Atrial tissue fibrosis has previously been identified using delayed-enhancement MRI (DE-MRI) in patients with atrial fibrillation (AF). Although the clinical importance of DE-MRI is well recognized, the visualization of atrial fibrosis and radiofrequency (RF) lesions has still not been achieved in Japan, primarily because of the differences in contrast agents, volume-rendering tools, and technical experience. The objective of this study was to visualize RF lesions by using commercially available tools. METHODS: DE-MRI was performed in 15 patients who had undergone AF ablation (age, 59±4 years, left atrium diameter, 40±2 mm). Specific parameters for MR scanning obtained from previous reports were modified. RESULTS: Of the 15 images, the images of three patients were uninterpretable owing to low image quality. RF lesions could be visualized in 8 (67%) of the 12 patients. CONCLUSIONS: In the current study, we successfully demonstrated that RF lesions could be visualized in Japanese patients using DE-MRI, although only commercially available tools were used.

AI evidence extraction

At a glance
Study type
Other
Effect direction
unclear
Population
Patients with atrial fibrillation who had undergone AF ablation (Japan)
Sample size
15
Exposure
radiofrequency ablation (cardiac)
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

DE-MRI was performed in 15 post-ablation AF patients; 3/15 images were uninterpretable due to low image quality. RF lesions were visualized in 8 of 12 interpretable cases (67%).

Outcomes measured

  • Ability to visualize radiofrequency (RF) ablation lesions using delayed-enhancement MRI (DE-MRI)
  • Image interpretability/quality

Limitations

  • Small sample size (n=15)
  • 3/15 scans uninterpretable due to low image quality
View raw extracted JSON
{
    "study_type": "other",
    "exposure": {
        "band": null,
        "source": "radiofrequency ablation (cardiac)",
        "frequency_mhz": null,
        "sar_wkg": null,
        "duration": null
    },
    "population": "Patients with atrial fibrillation who had undergone AF ablation (Japan)",
    "sample_size": 15,
    "outcomes": [
        "Ability to visualize radiofrequency (RF) ablation lesions using delayed-enhancement MRI (DE-MRI)",
        "Image interpretability/quality"
    ],
    "main_findings": "DE-MRI was performed in 15 post-ablation AF patients; 3/15 images were uninterpretable due to low image quality. RF lesions were visualized in 8 of 12 interpretable cases (67%).",
    "effect_direction": "unclear",
    "limitations": [
        "Small sample size (n=15)",
        "3/15 scans uninterpretable due to low image quality"
    ],
    "evidence_strength": "low",
    "confidence": 0.7399999999999999911182158029987476766109466552734375,
    "peer_reviewed_likely": "yes",
    "keywords": [
        "atrial fibrillation",
        "delayed-enhancement MRI",
        "DE-MRI",
        "radiofrequency ablation",
        "lesion visualization",
        "image quality"
    ],
    "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.